CR0708 CR0709
7
5 Installation
5.1 Installation location
The following installation locations are permitted:
•
inside of the cabin
•
body
•
vehicle frame
Installation on the motor/engine is not permitted.
For non-mobile applications, the applicable directives are to be adhered to, taking into account the
specified environmental conditions.
ATTENTION
Excessive current, weld slag and soiling due to welding
w
Damage to the device, deterioration of the electrical safety
u
Welding work on the chassis frame must only be carried out by qualified personnel.
u
Remove and cover the plus and minus terminals of the batteries.
u
Disconnect all contacts of the device from the on-board system prior to welding on the
vehicle or machine.
u
Connect the earth terminal of the welding device directly to the part to be welded.
u
Do not touch the device or electric cables with the welding electrode or the earth
terminal of the welding device.
u
Protect the device incl. all connectors and all connection cables against weld slag and
soiling.
5.2 Mounting surface
The housing must not be exposed to any torsional forces or mechanical stress.
u
Use suitable compensating elements if there is no flat mounting surface available.
Fig. 1: Mounting surface