4 Installation

4.1 Installing E80392

E80392 is suitable for installation on a rectangular type RFID read/write head (e.g. ANT515 /
ANT516).

If E8039x is mounted on metal or in the vicinity of metal, the range of the RFID read/write head
is reduced.

u

Mount the E8039x at least 100 mm away from metal objects.

The range is reduced to 20 % if the distance to the metal is approx. 5 mm.

The range is reduced to 40 % if the distance to the metal is approx. 10 mm.

Installing the E80392:

u

Place the RFID read/write head in the cut-out of the E80392 (see next figure).

w

The sensing face of the RFID read/write head must point in the direction of the E80392.

Fig. 1: The RFID read/write head is placed in the cut-out of the E80392.

u

Screw the RFID read/write head to the E80392 with 2x M3x6 lens screws.

u

Turn the E80392 over (see next figure).

w

The sensing face of the RFID read/write head points upwards.

Содержание E80392

Страница 1: ...Operating instructions RFID antenna adapter E80392 11532055 00 05 2023 GB...

Страница 2: ...ote 3 1 1 Symbols used 3 1 2 Legal and copyright information 3 2 Safety instructions 4 3 Intended use 5 4 Installation 6 4 1 Installing E80392 6 5 Technical data 8 5 1 E80392 detection range 8 6 Maint...

Страница 3: ...nation of keys buttons or indications Cross reference Important note Non compliance may result in malfunction or interference Information Supplementary note 1 2 Legal and copyright information All rig...

Страница 4: ...ts intended purpose Intended use If the operating instructions or the technical data are not adhered to personal injury and or damage to property may occur The manufacturer assumes no liability or war...

Страница 5: ...an accessory for rectangular type RFID read write heads The accessory is used to change the field of the connected RFID read write head This leads to the following effects depending on the installati...

Страница 6: ...o 20 if the distance to the metal is approx 5 mm The range is reduced to 40 if the distance to the metal is approx 10 mm Installing the E80392 u Place the RFID read write head in the cut out of the E8...

Страница 7: ...RFID antenna adapter E80392 7 1 Fig 2 Turned E80392 Mounting holes u Use the mounting holes to fix the E80392 to a suitable surface...

Страница 8: ...gure below shows the detection range of an ANT515 with and without E80392 A 50 mm tag E80384 was used for the measurement 0 50 100 150 300 350 100 80 60 40 20 mm mm 200 250 50 100 150 200 250 300 350...

Страница 9: ...ifm in case of malfunction u Do not open the housing as the unit does not contain any components which can be maintained by the user The unit must only be repaired by the manufacturer u Clean the dev...

Страница 10: ...rovals and standards the following information is available Test standards and regulations documentation ifm com EU declaration of conformity and approvals documentation ifm com Notes relevant for app...

Отзывы: