E30430
IO-Link INLINE DISPLAY 1.44"
14
u
In the [Compatible IODDs] tab, select the device catalogue and confirm with [Import].
u
Write the device catalogue to the display.
w
A note on the compatibility mode of the AL master is displayed. The port configuration of the
master port is automatically reconfigured. If necessary, this should be changed back after the write
process.
u
Acknowledge with [OK].
w
When the write process is finished, the new device catalogue is integrated in the display.
Do not disconnect the display from the IO-Link master during the write process. Otherwise the
update of the device catalogue is faulty and needs to be repeated.
u
Restart the INLINE DISPLAY with [Power Off / On] (note port configuration).
10.2.4 Resetting the AL master port
When the catalogue is written, the master port switches to compatibility mode. This is necessary for
the AL IO-Link master to be able to transfer the catalogue to the display.
u
Via moneo, switch to the settings of the AL master and set the port back to the original setting or
[No check and clear]. If necessary, set the vendor and device ID to default.