1  Preliminary note

Technical data, approvals, accessories and further information at  

www�ifm�com�

1.1  Key to the symbols

Instructions

>

Reaction, result

[…] Designation of keys, buttons or indications

Cross-reference
Important note 

Non-compliance may result in malfunction or interference�
Information 

Supplementary note�

WARNING 

Warning of serious personal injury� 

Death or serious irreversible injuries may result�

CAUTION 

Warning of personal injury� 

Slight reversible injuries may result�

ATTENTION 

Warning of damage to property

Содержание DV 500 Series

Страница 1: ...Operating instructions 5 segment signal lamp DV15x0 DV25x0 80263024 00 07 2019 UK ...

Страница 2: ...ation 8 6 1 IO Link device DV25x0 8 6 2 Standard device DV15x0 8 7 Operating and display elements 9 8 Operation 10 8 1 Operation of the IO Link version 10 8 1 1 General 10 8 1 2 On off mode 10 8 1 3 RGB mode 11 8 1 4 Analogue mode 12 8 2 Operation of the standard version 14 8 3 Demo mode 14 9 Parameter setting 14 9 1 IO Link version 14 9 2 Standard version 15 9 2 1 Parameter structure 16 10 Scale ...

Страница 3: ...3 UK 11 Technical data 21 11 1 IO Link device 21 12 Maintenance repair and disposal 22 12 1 Cleaning the housing surface 22 13 Approvals standards 22 ...

Страница 4: ...ion of keys buttons or indications Cross reference Important note Non compliance may result in malfunction or interference Information Supplementary note WARNING Warning of serious personal injury Death or serious irreversible injuries may result CAUTION Warning of personal injury Slight reversible injuries may result ATTENTION Warning of damage to property ...

Страница 5: ...tect units and cables against damage 3 Functions and features The unit is used to visually display machine conditions The versions DVx510 and DVx530 additionally have a buzzer for acoustic signalling The 5 LED segments and the audible warning device can be switched on and off individually The device is intended for indoor use only Observe the operating conditions 11 Technical data The unit must no...

Страница 6: ...he unit detailed information about process data structure diagnostic information parameter addresses and the necessary information about the required IO Link hardware and software can be found at www ifm com 4 Installation Disconnect power before installation For installation choose a flat mounting surface 1 18 43 20 M4 4 Fixture view from bottom 1 Front side Attach the fixture for the unit to the...

Страница 7: ... to fix it Observe the maximum tightening torque of the connection cable Integrated seals at the bottom of the fixture and in the base as well as O rings at the fixture and base prevent ingress of moisture More information about available accessories at www ifm com 5 Electrical connection The unit must be connected by a qualified electrician The national and international regulations for the insta...

Страница 8: ...nt 5 2 buzzer DV1510 and DV1530 3 LED segment 3 4 LED segment 2 5 voltage supply 6 LED segment 1 7 LED segment 4 8 IO Link 6 2 1 4 5 7 3 8 The input polarity is selectable Connect pin 5 to 24 V DC to trigger the inputs with an NPN transistor Connect pin 5 to GND to trigger the inputs with a PMP transistor When triggered via IO Link pin 8 without connection cable E12572 Connect pin 5 to 24 V DC Con...

Страница 9: ... Parameter setting button only DV15x0 2 LED segment 1 with 4 RGB LEDs 3 LED segment 2 with 4 RGB LEDs 4 LED segment 3 with 4 RGB LEDs 5 LED segment 4 with 4 RGB LEDs 6 LED segment 5 with 4 RGB LEDs 7 Buzzer only DVx510 and DVx530 8 Feedback LED only DV15x0 ...

Страница 10: ...er only with DVx510 and DVx530 on and off PDout cyclical data communication Signalling corresponds to the pre defined parameters for the individual LED segments and the buzzer Via the acyclic parameter setting the following properties can be set for every LED segment Colour red green orange blue violet turquoise white yellow off Frequency permanently on low flash rate slow medium fast high flash r...

Страница 11: ...g 1 blue Byte 0 Segment 2 LED properties Seg 2 yellow Seg 2 red Seg 2 green Seg 2 blue Byte 1 Segment 3 LED properties Seg 3 yellow Seg 3 red Seg 3 green Seg 3 blue Byte 2 Segment 4 LED properties Seg 4 yellow Seg 4 red Seg 4 green Seg 4 blue Byte 3 Segment 5 LED properties Seg 5 yellow Seg 5 red Seg 5 green Seg 5 blue Byte 4 Buzzer sound buzzer style 1 8 Buzzer Byte 5 The properties of the LED se...

Страница 12: ...n the controller transmits an analogue value between 0 and 100 in byte 0 via PDout Byte 1 determines the representation of the visual signalling 9 different representations are possible Byte 5 defines the acoustic signal only with DVx510 and DVx530 8 different acoustic signals are available 7 6 5 4 3 2 1 0 PDout Analogue value 0 100 Byte 0 Representation LED style 1 9 Byte 1 Byte 2 Byte 3 Byte 4 B...

Страница 13: ...e white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white white Segment 5 Segment 4 Segment 3 Segment 2 Segment 1 Segment 5 Segment 4 Segment 3 Segment 2 Segment 1 Style 8 Style 9 green green green green green green green green green green green green green green green green ...

Страница 14: ...requency permanently on low flash rate slow medium fast high flash rate slow medium fast Brightness 100 75 50 25 Parameter setting via the IO Link interface pin 8 of the M12 connector is also possible After parameter setting the unit goes to the Run mode 8 3 Demo mode In demo mode the unit demonstrates the different colours visual indications of analogue values styles buzzer sounds buzzer styles p...

Страница 15: ...ng button 5 s to change the value for the selected parameter Repeat this step until the requested setting is selected The unit indicates the current settings of the LED segment to be configured Press the parameter setting button for a longer time 5 s to save the selected value for this parameter The feedback LED flashes green The unit saves the value and goes to the next parameter After configurat...

Страница 16: ...ess 100 75 50 25 3 Colour red green orange blue violet turquoise white yellow off Frequency on lowflash rate slow lowflash rate medium lowflash ratefast high flashrate slow high flashrate medium high flashrate fast Brightness 100 75 50 25 4 Colour red green orange blue violet turquoise white yellow off Frequency on lowflash rate slow lowflash rate medium lowflash ratefast high flashrate slow high ...

Страница 17: ...17 UK 10 Scale drawing 10 1 DVx500 EPS Source Product Scale Draw Frame Size 80 mm Original Scale Draw Z_e200_0097 Scale 1 2 M4x1 70 344 213 17 100 25 14 M12x1 15 18 40 Dimensions mm ...

Страница 18: ...18 10 2 DVx510 EPS Source Product Scale Drawing Frame Size 80 mm x 90 Original Scale Drawing M 0_0096 Scale 1 2 70 384 213 57 100 25 14 M4x1 1 M12x1 15 18 40 1 Buzzer Dimensions mm ...

Страница 19: ...19 UK 10 3 DVx520 EPS Source Product Scale Dra Frame Size 80 mm Original Scale Draw Z_e200_0099 Scale 1 2 M4x1 70 244 213 17 15 14 M12x1 18 40 M4x1 70 244 213 17 15 14 Dimensions mm ...

Страница 20: ...20 10 4 DVx530 EPS Source Product Scale Drawing Frame Size 80 mm x 72 70 284 213 57 15 14 M4x1 1 M12x1 18 40 284 213 1 1 Buzzer Dimensions mm ...

Страница 21: ... 50 Storage temperature C 40 75 Max permissible relative humidity 90 Maximum operating altitude m 2000 above sea level Permissible air pressure hPa 1060 IO Link Connectors M12 connector 8 poles M12 connector 4 poles 11 1 IO Link device Transmission type COM2 38 4 kbaud IO Link revision 1 1 SDCI standard IEC 61131 9 IO Link device ID DV15xx 850 d 00 03 52 h DV25xx 841 d 00 03 49 h SIO mode Yes Inpu...

Страница 22: ...h the applicable national regulations 12 1 Cleaning the housing surface Disconnect the device Clean the device from dirt using a soft chemically untreated and dry cloth In case of heavy dirt use a damp cloth Micro fibre cloths without chemical additives are recommended 13 Approvals standards EC declarations of conformity approvals etc at www ifm com ...

Отзывы: