15
UK
9.2 Standard version
►
Turn the transparent protective cover anticlockwise by approx� 10 ° and remove
it�
►
Briefly press the parameter setting button at the head of the unit (< 5 s)�
> The feedback LED is green on�
The unit is in the parameter setting mode�
►
Briefly press the parameter setting button (< 5 s) to go to the next parameter�
►
Press the parameter setting button for a longer time (> 5 s) to set the selected
parameter�
> The feedback LED flashes green�
The unit indicates the current settings of the LED segment to be configured�
►
Briefly press the parameter setting button (< 5 s) to change the value for the
selected parameter� Repeat this step until the requested setting is selected�
> The unit indicates the current settings of the LED segment to be configured�
►
Press the parameter setting button for a longer time (> 5 s) to save the selected
value for this parameter�
> The feedback LED flashes green�
The unit saves the value and goes to the next parameter�
> After configuration of all LED segments the unit displays the current settings of
all LED segments�
►
Briefly press the parameter setting button (< 5 s) to finish the parameter setting
mode�
> The feedback LED goes out� The unit is in the Run mode�
If the parameter setting button is not pressed for longer than 30 seconds,
the unit saves the last changes and goes to the Run mode�