11 Troubleshooting

Display

LED

Error

Troubleshooting

I

Power

II

OFF

off

off

off

Supply voltage too low.

Check/correct the supply voltage:
Electrical connection

SC

flashes

any

flashes

Excessive current at the switching
output OUTx (see LED I/II).

Check switching output for short
circuit or excessive current. Re-
move the fault.

C.Loc

any

any

any

Parameter setting via pushbuttons
locked due to active IO-Link trans-
mission.

Wait until parameter setting via
IO-Link is finished.

S.Loc

any

any

any

Parameter setting via pushbuttons
disabled by software.

Unlocking only possible via IO-
Link interface/IO-Link parameter
setting software.

Loc

any

any

any

Parameter setting via pushbuttons
disabled.

Unlock pushbuttons:
Locking / unlocking (

Ò

 

/

 20)

Rotating seg-
ment

any

any

any

Temperature in housing exceeds
limit value.

Press any button to switch the dis-
play on for 30 s.

DEUC

any

on

any

Device identification activated (sys-
tem command: FLASH_ON)

Deactivate device identification
(system command: FLASH_OFF)

Содержание DP2402

Страница 1: ...Operating instructions Pulse stretcher DP2402 11420212 00 01 2022 GB...

Страница 2: ...15 8 3 1 OUt1 output OUT1 15 8 3 2 OUt2 output OUT2 16 8 3 3 EF extended functions 16 8 4 Parameters for OUT1 16 8 4 1 ou1 output configuration 16 8 4 2 dIn1 input configuration 16 8 4 3 dS1 switch o...

Страница 3: ...DP2402 3 9 2 Notes on programming 20 9 2 1 Locking unlocking 20 9 2 2 Timeout 20 9 2 3 Numerical entries with or 20 10 Operation 21 11 Troubleshooting 22 12 Maintenance repair and disposal 23 13 Fact...

Страница 4: ...uctions Reaction result Designation of keys buttons or indications Cross reference Important note Non compliance may result in malfunction or interference Information Supplementary note 1 2 Warnings u...

Страница 5: ...eep it during the entire service life The product must be suitable for the corresponding applications and environmental conditions without any restrictions Only use the product for its intended purpos...

Страница 6: ...belt 2 Pulse generator on the conveyor belt 3 DP2402 4 Transistor output 5 PLC evaluation units The unit is not suited for environments with particular requirements on mechanical stability e g shock...

Страница 7: ...Pulse stretcher DP2402 7 3 1 Temperature derating depending on the altitude 0 1000 2000 3000 4000 h m 60 50 40 30 20 10 TA C 52 48...

Страница 8: ...k capable module IO Link master The IO Link interface allows direct access to the process and diagnostic data and enables setting of the parameters of the unit during operation You will find further i...

Страница 9: ...ion properly until there is at least one rising edge at the input 4 2 2 Input configuration edge controlled The edge of the input signal is the trigger for the output of pulses at the output The durat...

Страница 10: ...nit are protected from mechanical stress such as shock and vibration u If necessary fix the unit with a clamp use M4 screw or cable tie Fig 5 Mounting clip Fig 6 Mounting clip with attached unit The m...

Страница 11: ...lternatively supply the unit via a limited energy circuit according to IEC 61010 1 or class 2 according to UL1310 Output reaction to overload or short circuit For self protection of the output in case...

Страница 12: ...u Carry out the fitting according to the indications of the cable manufacturer Maximum tightening torque on the connector side 1 8 Nm Maximum tightening torque o the socket side 1 3 0 1 Nm 6 2 Removin...

Страница 13: ...the parameter and acknowledgement of a parameter value Down Selection of a parameter Setting a parameter value scrolling by holding down incremen tally by pressing repeatedly Up To ensure correct oper...

Страница 14: ...DP2402 Pulse stretcher 14 7 3 Indication Colour Designation Red 7 segment LED display 4 digits Error signals and diagnostics Troubleshooting In operating mode no value is shown on the display...

Страница 15: ...nk interface Parameters adjustable via IO Link If the unit was locked via IO Link it can also only be unlocked via the IO Link interface Locking unlocking 20 8 2 Menu structure ou1 OFF no nc Edg dln1...

Страница 16: ...lse with defined duration for a rising edge at the input EdG output of a pulse with defined duration for a falling edge at the input 8 4 3 dS1 switch on delay Delay when the output OUT1 changes to the...

Страница 17: ...configuration 8 5 4 dr2 switch off delay Delay when the output OUT2 changes to the idle state This function is only available if PULS is selected as input configuration 8 5 5 h t2 hold time Definitio...

Страница 18: ...ours Operating times of less than one full hour are not saved Counter readings are saved permanently 8 7 5 Application specific tag Customer specific application description max 32 characters long Def...

Страница 19: ...er here OUt2 u Press until OUt2 is displayed u Press to get to the extended functions menu w The first parameter of the extended functions is displayed 3 Change to the programming mode of the paramete...

Страница 20: ...the unit is not locked Customer locking If C Loc is displayed when an attempt is made to modify a parameter value an IO Link communication is active temporary locking Software locking If S Loc is disp...

Страница 21: ...in the operating mode SIO It carries out its measurement and evaluation functions and provides output signals according to the set parameters Menu The normal operating mode is SIO mode as real time tr...

Страница 22: ...ked due to active IO Link trans mission Wait until parameter setting via IO Link is finished S Loc any any any Parameter setting via pushbuttons disabled by software Unlocking only possible via IO Lin...

Страница 23: ...anufacturer is allowed to repair the unit u After use dispose of the device in an environmentally friendly way in accordance with the applicable national regulations Cleaning the unit u Disconnect the...

Страница 24: ...LS PULS EDG EDG dS1 Switch on delay OUT1 0 ms 0 9999 ms dr1 Switch off delay OUT1 0 ms 0 9999 ms h t1 Hold time OUT1 200 ms 1 9999 ms ou2 Output configuration OUT2 no OFF no nc dln2 Input configuratio...

Отзывы: