Speed monitor
DP2122
21
8.3.2 SSC2 ─ speed monitor OUT2
The parameter opens the menu of the settings for OUT2 of the speed monitor.
8.3.3 EF ─ extended functions
The parameter opens the extended functions menu.
8.4 Parameters for OUT1 (SSC1)
8.4.1 ModE ─ switch point mode
Setting of the switch point mode.
•
[1-p] = Single point mode (
•
[and] = Window mode (
•
[2-p] = Two point mode (
•
[OFF] = Deactivated mode (
8.4.2 LoGc ─ switch point logic
Setting of the switch point logic: Function diagrams (
•
[no] = switch is closed when activated.
•
[nc] = switch is opened when activated.
8.4.3 SP1 ─ switch point 1
Threshold for the upper switch point.
In "Single point mode" SP1 is adjustable over its entire value range. In "Two point mode" and
"Window mode" the lower limit is restricted by SP2. It always applies: SP1 > SP2.
8.4.4 SP2 ─ switch point 2
Threshold for the lower switch point.
Only active in the switch point modes "Two point mode" and "Window mode".
In "Single point mode" the existing setting of SP2 is ignored. When changing to "Two point
mode" or "Window mode", SP2 is automatically adjusted. It always applies: SP2 < SP1.
SP1 limits the maximum setting value of SP2. It always applies: SP2 < SP1.
8.4.5 HyS ─ switch points hysteresis
Setting of the hysteresis with respect to switch points SP1 and SP2 Function diagrams (
Only active in the switch point modes "Single point mode" and "Window mode".
Setting range: 0.5...100 %,
Resolution 0.1 %
GB