7
UK
3 Functions and features
The freely programmable controllers of the "ecomatController" series are rated for
use under difficult conditions: this includes an extended temperature range, strong
vibration, intensive EMC interference�
This is a class A product� This product may cause radio interference in
domestic areas�
►
If required, take appropriate EMC screening measures�
• Safety controller for mobile machinery applications�
• Two separately programmable controllers:
-safe PLC for safety-related applications
-non-safe PLC for standard applications
-CODESYS V3�5 programming system (in a version approved by ifm) for
both controllers� The safe controller requires a safety SIL2 extension for
CODESYS�
• For applications operating according to the normally closed principle, for which
the safety functions can be implemented, the following applies: safe state =
power-free state (power-free output, switched off)�
• For the supply of the controller (on-board system, PELV power supply):
• Multifunctional inputs and outputs the operating mode (e�g� current, voltage,
frequency input; PWM, digital output) and use of which can be configured in
one of the controllers�
• Sensors and actuators can (depending on the required input and/or output
type) be connected either as single or dual channel and be used as a safe
device�
• Connection of sensors or actuators via CAN interfaces� Connection to other
controllers via CAN� Implementation of a safe communication via CANopen
Safety�
• Use the device only within the limits of the technical data
For the controller, no direct connection to IT structures is intended� If this
application is required, the users have to implement it (e�g� by using their
own additional components)�