12
10 Technical data
The data sheets are available on our website at:
www�ifm�com
10.1 Detection range with E80384
0
-50
-150
170
220
120
20
[mm]
[mm]
-100
-200
50
100
150
200
70
Detection range at 100 % HF power
Detection range at 75 % HF power
Detection range at 50 % HF power
Individual ID tags require 100 % transmission power for correct reading and
writing�
►
In case of reduced transmission power, check the reading and writing
range of the ID tags�
All indications apply to static write operations� If not otherwise stated they
refer to the installation of the unit and of the ID tag in a non-metallic envi-
ronment�
The transmitter power can be set to 50, 75 or 100% via the device configu-
ration�