background image

12

10  Technical data

The data sheets are available on our website at: 

www�ifm�com

10.1  Detection range with E80384

0

-50

-150

170

220

120

20

[mm]

[mm]

-100

-200

50

100

150

200

70

  Detection range at 100 % HF power
  Detection range at 75 % HF power
  Detection range at 50 % HF power

Individual ID tags require 100 % transmission power for correct reading and 

writing�

 

In case of reduced transmission power, check the reading and writing 

range of the ID tags�

All indications apply to static write operations� If not otherwise stated they 

refer to the installation of the unit and of the ID tag in a non-metallic envi-

ronment�
The transmitter power can be set to 50, 75 or 100% via the device configu-

ration�

Содержание ANT600

Страница 1: ...Installation Instructions RF identification system Read write head ANT600 80256821 00 10 2017 UK...

Страница 2: ...mounting 6 5 3 Avoiding interference 7 5 4 Mechanical design 7 5 5 Mounting options 7 5 5 1 Installation with angle bracket E80335 7 5 5 2 Installation with mounting device E80336 8 5 5 3 Installation...

Страница 3: ...3 UK 12 1 1 Overview 13 12 1 2 Europe 13 12 2 EC declaration of conformity 13...

Страница 4: ...ons 2 1 General Observe the operating instructions Non observance of the instructions operation which is not in accordance with use as prescribed below wrong installation or incorrect handling can aff...

Страница 5: ...is not designed for use in domestic areas The unit may only be used under the operating conditions specified in the data sheet 3 Functions and features In connection with the evaluation unit DTE10x t...

Страница 6: ...rful HF emission sources such as welding transformers or converters can affect operation of the read write heads Information on the available mounting accessories is available on our website at www if...

Страница 7: ...Such devices are for example frequency converters and switched mode power supplies 5 4 Mechanical design 1 2 1 Sensing face 2 Connection can be rotated by 270 5 5 Mounting options For installation th...

Страница 8: ...ed to mount the unit to a clamp The following clamps can be used E21110 with a rod diameter of 12 mm E20795 with a rod diameter of 14 mm E21109 with a rod diameter of 14 mm 5 5 3 Installation with fix...

Страница 9: ...Mounting distances Operating mode Distance side A Distance front B For reading and writing at 100 transmitter power 600 mm 400 mm 5 7 Positioning of the ID tags D Align the ID tag on the antenna cent...

Страница 10: ...vailable on our website at www ifm com Cables with the following characteristics are suitable for the connection Length Ohmic resistance feed return line Effective cable capacity 20 m max 3 max 3 nF 7...

Страница 11: ...nfigurable The max receive signal strength depends on the type of the ID tag 8 Operation The read write head is configured via the connected evaluation unit DTE10x You can find more information about...

Страница 12: ...ion range at 50 HF power Individual ID tags require 100 transmission power for correct reading and writing In case of reduced transmission power check the reading and writing range of the ID tags All...

Страница 13: ...r the unit After use dispose of the unit in an environmentally friendly way in accordance with the applicable national regulations 12 Approvals standards 12 1 Radio approvals 12 1 1 Overview The overv...

Отзывы: