ANT515 ANT516
13
7 Operating and display elements
1
2
Fig. 7: Operating and display elements
1 LED
2 Sensing face
LED
State
Description
green
On
Operating voltage OK
Off
Operating voltage missing
Flashing slowly
deactivated
yellow
On (permanently)
ID tag detected
On (pulse)
ID tag read/written successfully
Flashing quickly
Error when reading/writing on ID tag
Off
• no ID tag in the field
• faulty ID tag in the field
• invalid ID tag in the field
green and yellow
Flashing alternately
Error in communication or device fault