IO-Link master with EtherCAT interface DataLine 4 ports IP 65 / IP 66 / IP 67
16
6.4
IO-Link ports
51958
The IO-Link ports of the AL1330 meet the requirements of the IO-Link specifications 1.0 to 1.1.2.
► Please note the information concerning IO-Link wiring!
► Cover unused sockets with M12 protective caps (art. no.: E73004).
>
6.4.1
Connecting IO-Link devices for Class A operation
51959
Wiring information:
•
The connected IO-Link devices must be supplied exclusively via the IO-Link master.
•
The additional digital inputs IO-Link ports X01...X04 (pin 2) have a type 2 behaviour according to
the standard EN61131-2. The connected electronics must be electrically suited for this.
► Connect the connectors of the IO-Link devices with the M12
sockets of the IO-Link ports X01...X04.
▪
Maximum cable length per IO-Link port: 20 m
► To connect the devices, use M12 connectors with protection
rating IP 65 / IP 66 / IP 67 or higher (
→
Accessories
(
)).