1  Preliminary note

Technical data, approvals, accessories and further information at  

www�ifm�com�

1.1  Symbols used

Instructions

Cross-reference
Important note 

Non-compliance may result in malfunction or interference�
Information 

Supplementary note�

2  Safety instructions

•  Read this document before setting up the product and keep it during the entire 

service life�

•  The product must be suitable for the corresponding applications and 

environmental conditions without any restrictions�

•  Only use the product for its intended purpose (→ Functions and features).
•  If the operating instructions or the technical data are not adhered to, personal 

injury and/or damage to property may occur� 

•  The manufacturer assumes no liability or warranty for any consequences 

caused by tampering with the product or incorrect use by the operator�

•  Installation, electrical connection, set-up, operation and maintenance of the 

product must be carried out by qualified personnel authorised by the machine 

operator�

•  Protect units and cables against damage�

3  Functions and features

•  maximum number of modules per master: 62 
•  AS-Interface version 3�0, backwards compatible

Содержание AC2396

Страница 1: ...Operating instructions AS i illuminated pushbutton module AC2386 AC2388 AC2396 AC2398 80270506 03 09 2019 UK...

Страница 2: ...4 1 Fitting of the illuminated pushbuttons AC2386 AC2396 4 5 Electrical connection 4 5 1 Pin connection data bits 5 5 2 Data bits AC2386 AC2388 5 5 3 Data bits AC2396 AC2398 5 6 Addressing 6 7 Operat...

Страница 3: ...any restrictions Only use the product for its intended purpose Functions and features If the operating instructions or the technical data are not adhered to personal injury and or damage to property...

Страница 4: ...covers into the requested position Turn them so that the 4 cross shaped grooves are located over the ridge cross of the holder Slightly press the cover until it snaps into place You can remove the co...

Страница 5: ...A E extended addressing mode yes AC2396 2 inputs 2 outputs 2 NO 2 LEDs white 10 colour plates red green yellow white blue AS i profile S B A E extended addressing mode yes AC2398 2 inputs 2 outputs 1...

Страница 6: ...to 0 at the factory Assign a free address between 1A and 31B Addressing unit AC1154 Wiring of the addressing socket 1 AS i 2 TTL 3 AS i 4 TTL 5 5 V 7 Operating and display elements 7 1 AC2386 AC2396 1...

Страница 7: ...tage supply OK LED FAULT red on AS i communication error slave does not participate in the normal exchange of data e g slave address 0 9 Maintenance repair and disposal The operation of the unit is ma...

Отзывы: