9.6 Setting of the preset meter / pulse value (ImPS)
7 setting ranges are available:
LED
indication
in steps o
value
1
3
0 �0 0 1
���
9 �9 9 9
0�001 Nm³
0�001���9�999 Nm³
2
3
1 0 �0 0
���
9 9 �9 9
0�01 Nm³
10�00���99�99 Nm³
3
3
1 0 0 �0 ���
9 9 9 �9
0�1 Nm³
100�0���999�9 Nm³
4
3
1 0 0 0
���
9 9 9 9
1 Nm³
1000���9999 Nm³
5
3 + 5
1 0 �0 0
���
9 9 �9 9
10 Nm³
10 000���99 990 Nm³
6
3 + 5
1 0 0 �0 ���
9 9 9 �9
100 Nm³
100 000���999 900 Nm³
7
3 + 5
1 0 0 0
1 000 000 Nm³
Setting operation
:
► Ensure that [OU1] is set to [ImP]�
► Select [ImPS], press [Set] and keep it pressed�
> The current numerical value flashes for 5 s, then one of the 4 digits becomes
active (digit flashes, can be changed)�
► Set the requested value as indicated in the following table�
First select the requested setting range� Then set the figure from the left digit to
the right digit�
► Press [Mode/Enter] briefly when all 4 digits are set�
As soon as the first digit flashes there are 3 options:
► Press [Set] once
The flashing digit is increased� 9 is followed by 0 - 1 - 2, etc�
8 �1 2 3
[Set] pressed 1 x 9 �1 2 3
[Set] pressed 1 x 0 �1 2 3
[Set] pressed 1 x 1 �1 2 3