Diagnostic data output has the following structure:
I l l u m i n a t i o n T em p e r a-
t u r e
32-bit signed int 4 b yt e s
F r ontend T empera-
t u r e 1
32-bit signed int 4 b yt e s
F r ontend T empera-
t u r e 2
32-bit signed int 4 b yt e s
i . m x 6 T em pe r a t u r e
32-bit signed int 4 b yt e s
F r amet ime (planned) 3 2 - b i t u ns i gn e d
integer
4 b yt e s
F r a m er a t e
3 2 - b i t u ns i gn e d
integer
4 b yt e s
All temperature values have the unit 0.1 °C, invalid temperatures have the value 0x7FFF
(32767).
i.mx6 temperature is not measured in C3 sample. Therefor these temperatures have the
value 0x7FFF (32767).