10.3.3 Table repeatability and accuracy
Values for sampling rate 15 Hz, extraneous light of max. 10 klx*
Distance
in [m]
Repeatability
Accuracy
white
90 % remission
grey
18 % remission
white
90 % remission
grey
18 % remission
0�20���1�00
± 0�45 cm
± 0�6 cm
± 1�5 cm
± 1�6 cm
1�00���2�00
± 0�5 cm
± 0�8 cm
± 1�5 cm
± 1�8 cm
2�00���4�00
± 1�25 cm
± 1�9 cm
± 2�5 cm
± 3�0 cm
4�00���6�00
± 2�0 cm
± 3�0 cm
± 3�0 cm
± 4�0 cm
6�00���10�00
± 3�50 cm
± 5�0 cm
± 4�5 cm
± 6�0 cm
10�00���18�00
± 5�0 cm
—
± 6�0 cm
—
Values for sampling rate 15 Hz, extraneous light of 40 klx*
Distance
in [mm]
Repeatability
Accuracy
white
90 % remission
grey
18 % remission
white
90 % remission
grey
18 % remission
0�20���1�00
± 0�45 cm
± 0�6 cm
± 1�5 cm
± 1�6 cm
1�00���2�00
±0�5 cm
± 0�8 cm
± 1�5 cm
± 1�8 cm
2�00���4�00
± 1�6 cm
± 1�9 cm
± 2�5 cm
± 3�0 cm
4�00���6�00
± 2�4 cm
± 3�3 cm
± 3�5 cm
± 4�5 cm
6�00���10�00
± 5�0 cm
—
± 6�5 cm
—
*Range referred to black (6 % remission) ≤ 4000 mm.
The values apply at:
• constant ambient conditions (23°C / 960 hPa)
• only after unit powered up for 10 minutes