10.6 User settings (optional)
10.6.1 Setting of the standard unit of measurement for volumetric flow
► Select [Uni] and set the unit of measurement: [Lmin] or [m3h]�
The setting only has an effect on the volumetric flow value� The
counter values (consumed quantity) are automatically displayed in
the unit of measurement providing the highest accuracy�
10.6.2 Configuration of the standard display
► Select [SELd] and determine the standard measuring unit:
-[FLOW] = the current volumetric flow value in the standard unit of
measurement is displayed�
-[TOTL] = display indicates the current meter count in l, m
3
or 1000 m
3
�
-[TEMP] = the current medium temperature in °C is displayed�
► Select [diS] and set the update rate and orientation of the display:
-[d1] = update of the measured values every 50 ms�
-[d2] = update of the measured values every 200 ms�
-[d3] = update of the measured values every 600 ms�
-[rd1], [rd2], [rd3] = display as for d1, d2, d3; rotated by 180°�
-[OFF ] = the display is switched off in the operating mode�
10.6.3 Changing the direction of the flow rate measurement
► Select [Fdir] and set the direction of flow:
[+] = flow in the direction of the flow arrow (= factory setting)
[-] = flow against the flow arrow ► label over the arrow
10.6.4 Setting the output logic
► Select [P-n] and set [PnP] or [nPn]�
10.6.5 Setting the start-up delay
► Select [dST] and set the numerical value in seconds�
10.6.6 Setting the measured value damping
► Select [dAP] and set the damping constant in seconds (τ value 63 %).