liability for consequences of misuse by the operator� Improper installation and
use of the devices results in a loss of the warranty claims�
• Correct operation and compliance with the measurement accuracy can only
be ensured if the environmental conditions specified in the technical data are
adhered to� Ensure that the maximum pressure range, measuring range and
permitted ambient temperature are not exceeded�
3 Functions and features
The unit monitors the standard volume flow of gases�
It detects the 4 process variables flow velocity, volumetric flow quantity, consumed
quantity, medium temperature�
• Application:
-Argon (Ar)
-Carbon dioxide (CO
2
)
-Nitrogen (N
2
)
• Selection of the medium to be monitored → 10.6.8.
• All indications apply to standard volume flow to DIN ISO 2533, i�e� volume flow
at 14�69 psi, 59 °F and 0 % relative air humidity� The unit can be set to different
standard conditions (→ 10.6.5 and → 10.6.6).
• The general operating conditions of systems with gas filling apply�
• Pressure Equipment Directive (PED): Devices with a measuring section comply
with art� 3 sec� (3) of the Directive 97/23/EC and are designed and manufac-
tured for stable gases of the fluid group 2 in accordance with sound engineer-
ing practice�