background image

2

Function and features

This inductive sensor detects metals without contact and indicates their presence by 
providing a switched signal.
The nominal sensing range (S

n

) can be seen in the type designation on the type 

label on the unit; operating distance (S

a

) 0 ... 0,81 x S

n

; (values based on standard 

measurement with mild steel; a shorter sensing range for other metals).

Electrical connection

Disconnect power before connecting the sensor. Connection strictly to the indications 
on the type label. The unit can be used as normally open (

) or as normally

 

closed (

).

Installation

Mounting by means of a mounting device.
Adjust the unit. Adjustment is correct 
when the red LED 

does not 

light. Secure 

by means of the nuts provided so that it 
cannot work loose.

Non-flush installation.

2

1

c

 LED yellow / red     

d

 Target

Open space around the sensing face when mounted in metal:

3 x S

n

D

D

D

2 x Sn