Max. permissible flow rate:
70 l/m (4.2 m³/h).
Pressure loss (dP)
is dependent on the flow rate (Q).
26
dP [bar]
Q [l/min]
1,5
3
5
10
30 40 50 60 80 100
0,01
0,02
0,03
0,04
0,05
0,1
0,2
0,4
0,5
1,0
0,3
20
Q [m
3
/h]
0,1
0,2
0,3 0,4
1,0
1,5 2,0 2,5 3
4
5 6
0,6
Flow rate in l/min
0 ... 60
0 ... 50
Display range
Measuring /
operating range
0.0 ... 3.6
0.0 ... 3.0
Flow rate in m
3
/h
0.001 ... 100
×
10
3
Totalising meter in m
3
+5 ... +80
Temperature in °C