11 Technical data
11.1 Operating distance L
When selecting the operating distance it has to be taken into account that contour
detection becomes less reliable with decreasing size of the objects . The objects to
be detected should cover at least 5% of the field of view . For the operating di-
stance L depending on the applications please see the following table .
Types O2D220 / O2D227 (normal lens)
Operating distance L [mm]
50
75
100
200
400
1000
2000
Field of view size WxH [mm]
16x12
24x18
32x24
64x48
128x96
320x240
640x480
Resolution [mm]
0 .1
0 .2
0 .3
0 .4
0 .8
2 .0
4 .0
Types O2D222 / O2D229 (wide-angle lens)
Operating distance L [mm]
50
75
100
200
400
1000
2000
Field of view size WxH [mm]
33x24
50x36
66x47
132x94
264x189
660x472 1320x945
Resolution [mm]
0 .3
0 .4
0 .5
0 .9
1 .7
4 .0
8 .0
Types O2D224 / O2D225 (telephoto lens)
Operating distance L [mm]
50
75
100
200
400
1000
2000
Field of view size WxH [mm]
-
15x11
20x15
40x30
80x60
200x150
400x300
Resolution [mm]
-
0 .08
0 .12
0 .25
0 .52
1 .25
2 .52
11.2 Factory settings
Device settings
Parameters
Factory setting
Device name
New sensor
Device location
New location
DHCP
not active
IP address
192 .168 .0 .49
Subnet mask
255 .255 .255 .0
Gateway
192 .168 .000 .201
XML-RPC port
8080
Video port
50002
Application selection via switching inputs
not active
Trigger debouncing
not active
Process interface mode
TCP/IP
Process interface version
2
Process interface TCP/IP port
50010