ENGLISH
NB: Commissioning
Without any further settings the retro-reflective sensor is set to the
max. range. This means that for the detection of transparent objects
the retro-reflective sensor must be set as described below.
Setting procedure to prismatic reflector*
• Align the unit in such a way that the prismatic reflector is hit.
• Press the push button briefly (for at least 50 ms).
The red LED starts to flash fast.
• Release the button.
The unit is in the operating mode.
Setting of the maximum sensitivity*
• Align the unit so that no light is reflected.
• Press the push button briefly.
• Release the button.
The unit is in the operating mode.
* The sensitivity can also be set in exactly the same way using the programming
wire (pin 2). To activate the functions the programming wire is connected for
the appropriate time to L+ (pin 1).
Electronic lock
Activate / deactivate the lock by connecting the programming wire for
about 15 s – 20 s (= connect pin 2 to L+).
6
push button
LED