background image

8

* The sensitivity can also be set in exactly the same way using the programming wire (pin 2 / 

WH) To activate the functions the programming wire is connected to L+ (pin 1 / BN) for PNP 

units or to L- (pin 3 / BU) for NPN units for the appropriate time Feedback: If setting was not 

successful via the programming wire, the output will switch for 2 s The unit then passes into 

the operating mode with the sensitivity being unchanged

If the setting of the sensitivity is not possible (eg object signal and back-

ground signal are about the same), the red LED flashes after step 3 for ap-

prox 2 s The unit then passes into the operating mode with the sensitivity 

being unchanged 

If the setting button is not activated for 15 minutes during the programming 

process, the unit passes automatically into the operating mode with the 

sensitivity being unchanged

7.3 Setting of the maximum sensitivity*

Go into the programming mode of the unit (→ step 1).

 

Interrupt the light beam

 

Press the setting button twice (→ steps 2 and 3).

 

* The maximum sensitivity can also be set in exactly the same way using the programming 

wire (pin 2 / WH) To activate the functions the programming wire is connected to L+ (pin 1 / 

BN) for PNP units or to L- (pin 3 / BU) for NPN units for the appropriate time

7.4 Electronic lock

Activate the lock by connecting the programming wire for about 15 s -20 s*
Deactivate the lock by connecting the programming wire again for 15 s - 20 s*

* To activate the functions the programming wire (pin 2 / WH) is connected to L+ (pin 1 / BN) 

for PNP units or to L- (pin 3 / BU) for NPN units for the appropriate time

7.5 Programming the output function*

Press for 10 s

 

The red LED starts to flash fast after 2 s

 

>

Then the yellow and green LEDs flash 

 

>

alternately

After 10 s all LEDs go off, the output func-

 

>

tion has changed from light-on mode to 

dark-on mode (or vice versa)

* The output function can be programmed in exactly the same way using the programming 

wire (Pin 2 /WH) To activate the functions the programming wire is connected to L+ (pin 1 / 

BN) for PNP units or to L- (pin 3 / BU) for NPN units for the appropriate time 

Содержание efector 200 OJ51 Series

Страница 1: ...Operating instructions Through beam sensor OJ51xx laser 704810 00 05 2010 UK...

Страница 2: ...on 4 5 Electrical connection 5 6 Setup 5 7 Settings 6 7 1 Setting of the sensitivity with stationary objects 6 7 2 Setting of the sensitivity with moving objects 7 7 3 Setting of the maximum sensitivi...

Страница 3: ...y instructions According to the cULus approval Caution Use of controls or adjustments or procedures other than those specified herein may result in hazardous radiation exposure Visible laser light CLA...

Страница 4: ...units with side lens are identical Secure the receiver OJELxx to a bracket Align the transmitter OJSLxx to the receiver and secure it in the same way Maximum range is only possible with precise alignm...

Страница 5: ...P L L 3 2 4 1 teach Transmitter DC 1 3 L L Programming of the output function by pushbutton or programming wire 7 5 Programming the output function 6 Setup The through beam sensor is supplied ready to...

Страница 6: ...bject Press once The yellow and green LEDs go out for approx 1 s After approx 3 s the green LED is on The unit is in the operating mode Setting steps 2 and 3 can also be carried out in reverse order T...

Страница 7: ...ramming mode of the unit Press for about 2 s until the red LED flashes The red LED goes out the yellow and green LEDs flash alternately The unit is in the programming mode 2 Allow objects to pass thro...

Страница 8: ...rupt the light beam Press the setting button twice steps 2 and 3 The maximum sensitivity can also be set in exactly the same way using the programming wire pin 2 WH To activate the functions the progr...

Страница 9: ...rnately 2 Hz output short circuited Flash alternately 1 Hz internal fault output is not switched 9 Maintenance repair and disposal Keep the lenses of the sensor free from soiling For cleaning do not u...

Отзывы: