Setting of the sensitivity

1

38

10

1

2

1: Einstellpotentiometer Tastweite
2: LED

Proceed as follows

 

Set the potentiometer to the smallest sensing range (1).

 

Place the object to be detected within the sensing range.

 

Increase the sensing range until the LED lights (= minimum value; object 
detected).

 

Remove the object from the sensing range (LED goes off).

 

Increase the sensing range until the LED lights (= maximum value; background 
detected).

 

Set the potentiometer to the medium position between minimum and maximum 
value.

Operation

 

Check the safe functioning of the sensor.

•  Dark-on switching units: the output is switched / the yellow LED is lit when no 

object is detected.

•  Light-on switching units: the output is switched / the yellow LED is lit when an 

object is detected.

Maintenance

 

Keep the lens of the sensor free from soiling.

 

For cleaning do not use any solvents or cleaning agents which could damage 
the plastic lenses.