Ethernet switch EC2095
6
4 Installation
4.1 Installation position and mounting surface
Installation position as required
No uneven mounting surface
NOTE
The housing must not be exposed to any torsional forces or mechanical stress.
Damage possible.
►
Fix the device only on plane surfaces.
►
Ensure that the contact area of the device lies completely flat on the moun-
ting surface.
4.2 Fixing
►
The device is fixed with 6 M5 screws. Tighten the screws alternately crosswise.
Mounting dimensions → 7 Technical data
Screw material: steel
Tightening torque: 8
±2
Nm
5 Electrical connection
5.1 Wiring
Wiring → 7 Technical data
NOTE
Wrong connection may cause damage to the device.
►
Observe the safety instructions.
►
First establish the Ethernet connections, then the supply voltage.
►
Basically all supply and Ethernet cables must be laid separately.