ENGLISH
C
LASSIC
C
ONTROLLER
CR0505
PAGE
9
ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen
18.09.2015
We reserve the right to make technical alterations without prior notice.
CR0505 / page 2
CR0505
Technical data
Operating voltage U
B
10...32 V DC
overvoltage
36 V for t
≤
10 s
undervoltage detection
for U
B
≤
10 V
switching-off in case of undervoltage
for U
B
≤
8 V
Current consumption
≤
160 mA (without external load at 24 V DC)
CAN interface 1
CAN interface 2.0 B, ISO 11898
Baud rate
50 kbits/s...1 Mbits/s (default setting 125 kbits/s)
Communication profile
CANopen, CiA DS 301 version 4, CiA DS 401 version 1.4
Node-ID (CANopen)
hex 7F (= dec. 127)
CAN interface 2
CAN interface 2.0 A/B, ISO 11898
Baud rate
50 kbits/s...1 Mbit/s (default setting 125 kbits/s)
Communication profile
SAE J 1939 or free protocol
Serial interface
RS-232 C
Baud rate
9.6 / 19.2 / 28.8 / 38.4 / 57.6 kBit/s (default setting 57.6 kbits/s)
Topology
point-to-point (max. 2 participants); master-slave connection
Protocol
predefined ifm protocol (INTELHEX)
Processor
CMOS microcontroller 16 bits C167CS
cycle frequency 20/40 MHz
Device monitoring
undervoltage monitoring
watchdog function
check sum test for program and system
excess temperature monitoring
Process monitoring concept
Two relays according to EN 954
monitor two groups of 4 outputs each
Physical memory
Flash: 2 MByte
RAM: 256 kByte
Remanent memory: 32 kByte
Memory allocation
See system manual
www.ifm.com
→
Data sheet search
→
CR0505
→
More information
Status indication
three-colour LED (R/G/B)
Operating states (Status-LED)
Test standards and regulations
Climatic test
Damp heat to EN 60068-2-30, test Db
(
≤
95% rel. humidity, non-condensing)
Salt mist test to EN 60068-2-52, test Kb, severity level 3
Degree of protection to EN 60529
Mechanical resistance
Vibration to EN 60068-2-6, test Fc
Shock to EN 60068-2-27, test Ea
Immunity to conducted interference
to ISO 7637-2, pulses 2, 3a, 3b, severity level 4, function state A
to ISO 7637-2, pulse 5, severity level 1, function state A
to ISO 7637-2, pulse 1, severity level 4, function state C
Immunity to interfering fields
according to UN/ECE-R10 at 100 V/m (E1 type approval)
and EN 61000-6-2 (CE)
Interference emission
according to UN/ECE-R10 (E1 type approval)
and EN 61000-6-3 (CE)
Tests for the approval
to BN 411 002 (DIN EN 50155 clause 10.2)
for railway applications
LED colour
Status
Description
–
off
no operating voltage
yellow
1 x on
initialisation or reset checks
green
5 Hz
no operating system loaded
green
2.0 Hz
Run
on
Stop
red
2.0 Hz
Run with error
on
fatal error or stop with error