iflo 121853 Скачать руководство пользователя страница 2

ZONE

0

Inside the bath or 

shower. Must be

SELV (12V max) due

to water submersion.

225cm above the

bath or shower.

1

The area stretching

to 60cm outside the

bath or shower and

60cm from water

outlet of sink.

2

Technical drawings are for illustration purposes only.

Make sure you check all hole cut outs before work commences.

INSTALLATION

Lift the cabinet from the packaging 

and position on a soft flat surface to 

avoid scratching the mirror.

The mirror must be installed with 

a minimum clearance of 150mm 

between the infrared sensor and any 

adjacent countertop or obstruction 

to ensure correct function of the 

sensor. 

Mark a desired height of the 

cabinet and draw a horizontal line on 

the wall which corresponds with the 

height of the cabinet hangers. Drill 

the required holes and insert the wall 

plugs using a stud detector to ensure 

you avoid any wiring or water pipes.

The wall plugs supplied are only 

suitable for solid stone/brick walls.

Screw the brackets to the wall using 

the screws provided. Please ensure 

they are fully tight.

1

Outside Zones.

Anywhere outside zones

0, 1 & 2. Where water jets

are not used for cleaning

purposes, the general

rules of BS7671 apply.

This mirror is IP44 rated

therefore suitable for

installation in zone 2 and

the outside zones.

Make sure to turn off the electrical 

supply at the mains, then connection 

must be made in accordance with the 

latest IEE regulations. This cabinet is 

manufactured to Class I and requires 

an earth connection.

Hang the cabinet on the wall bracket. 

The claws on the cabinet hangers 

must be securely located on the 

wall brackets. Use a spirit level to 

adjust the angle of the cabinet by 

turning screw A with a cross head 

screwdriver.

When the angle is properly adjusted, 

tighten screw B on both hangers. 

Then secure the base of the cabinet 

to the wall with the screw and

over-cap.

Close and secure the internal top 

electrical cover with the small screws 

removed earlier and switch on the 

electrical supply at the mains to test 

the function of the lamp and the 

shaver socket.

Insert the shelf supports in the 

desired positions starting with the 

top shelf. Insert the glass shelves 

and please make sure to tighten 

the plastic screw at the bottom of 

the shelf support to prevent the 

shelves becoming loose. Rubber 

plugs provided can be used to cover 

unused shelf holes.

If the doors are out of alignment, 

please first remove the soft-close 

buffer (from bottom hinges), then 

adjust the screws A, B and C on 

hinges for 3 directional adjustment, 

see diagram.

3

2

Waste Electrical & Electronic Equipment (WEEE)

The symbol on the product, or on the document accompanying the product, the

crossed out wheelie bin symbol, indicates that this product may not be treated

as household waste. Instead it shall be handed over to the applicable collection

point for the recycling of electrical and electronic waste.