Page
24
POWER AND METERING - STATUS RESPONSES FOR AMP
CODE
TWTA FUNCTION
POWERFWD
Returns Forward Power Value in Watts,
‘POWER FWD: XXXXX W’
POWERRFL
Returns Reflected Power Value in Watts,
‘POWER RFL: XXXXX W’
HELIXV
Returns Helix Volts Value in Volts,
‘HELIXV: XXXXX V’
HELIXI
Returns Helix Current Value in milliamps,
‘HELIXI: XXXXX mA’
COLLV
Returns Collector Volts Value in Volts,
‘COLLV: XXXXX V’
COLLI
Returns Collector Current Value in milliamps,
‘COLLI: XXXXX mA’
FILAMENTV
Returns Filament Volts Value in Volts,
‘FILAMENT V: XXXXX V’
[Optional]
GRIDV
Returns Grid Volts Value in Volts,
‘GRID V: XXXXX V’
[Optional]
FILAMENTH
Returns Filament Hours Value,
‘FIL HRS: XXXXX’
BEAMH
Returns Beam Hours Value,
‘BEAM HRS: XXXXX’
PULSEW
Returns Pulse Width Value,
‘PULS W: XXXXX.X uS’
[ In Pulse unit only ]
FRQNCY
Returns Pulse Frequency Value,
‘REP RATE: XXXXXX Hz’
[ In Pulse
unit only ]
DUTYCYC
Returns Duty Cycle Value,
‘DTY CYC: XXXXX %’
[ In Pulse unit only ]
ZEROATT
Sets the Amplifier for ZERO Attenuation & Returns,
‘GAIN: 00100 %’
[Optional]
FULLATT
Sets the Amplifier for FULL Attenuation & Returns,
‘GAIN: 00000 %’
[Optional]
MODEL
Returns Model number of the unit
SN
Returns Serial number of the unit
*IDN?
Returns ASCII response comprising of four data fields in the format
<Manufacturer>, <Model>, <Serial Number>, <Firmware Version>
*RST
Reset Command, Sets the Amplifier to the factory default power up state
(reboots MPU)