PRS-330 Series
ETHERNET INTERFACE OPTION
26
network settings.
VXI-11 Keyboard Control Program provides
interactive control of VXI-11 instruments from
the computer keyboard without having to write a
program. The VXI-11 Keyboard program is the
ideal utility program for con
fi
guring and testing
the PRS or any VXI-11 compatible instrument.
Use the VXI-11kybd program to exercise the
interface or to try out commands before using
them in a program. The VXI-11kybd program
can be found on the PRS product page at www.
ietlabs.com
Versatile Programming
The PRS-330 can be easily controlled by several
programming techniques and languages because
it is a VXI-11.3 instrument. If you program
with LabVIEW, National Instruments’ VISA
supports VXI-11.3 instruments like the PRS. NI’s
Measurement and Automation Explorer treats
the PRS as a TCP/IP compliant device. Agilent’s
VISA library supports VXI-11.3 instruments and
the Agilent Connection Manager sees the PRS as
a TCP/IP instrument.
If you are a Visual Basic, VB.Net or C/C++
programmer, you can write your program to
call Agilent’s or National Instruments’ VISA
or Agilent’s SICL library in the Windows
environment.
If you use LINUX or any other
fl
avor of UNIX
like SunOS, IBM-AIX, HP-UX, or Apple’s OS X,
you can communicate with the PRS through RPC
over TCP/IP. RPC (or Remote Procedure Calls)
provides an invisible communication medium for
the developer. The VXI-11 speci
fi
cation provides
an RPCL (Remote Procedure Call Library) that
can be used by virtually any operating system to
control the PRS.
If you program with Java then you can write a
PRS control program that can be easily moved
to many different operating systems.
The Java jGpibEnet project on SourceForge was
developed using an ICS 8065 Controller similar
to the PRS Controller.
5.4 Network Confi guration
This paragraph con
fi
gures the 9006 card in the
PRS for operation on your network. The board’s
digital interface is con
fi
gured later by sending
commands as outlined in Appendix A.
When shipped, the boards are con
fi
gured with
default settings outlined in Table 4-1 Default
Settings.
Command
Function
Factory Setting
IP Mode
Static or DHCP
Mode
Static
IP Address
0.0.0.0 to
255.255.255.255.0
192.168.1.254
Net Mask
0.0.0.0 to
255.255.255.255.0
255.255.255.0
COMM Timeout
Sets socket timeout
120 sec.
Auto Disconnect
Aborts socket if link
count goes to 0
Off
Table 4-1 Default Settings
Review the Table with your network administrator
and decide on which settings, if any, that need
to be changed. Table 4-1 provides detailed
information about each network setting to help
you with your decisions. The minimum change
is to set a static IP address so your PC can
communicate with the board.
NOTE:
After changing any Ethernet
Содержание PRS-330 series
Страница 2: ...TEL 516 334 5959 800 899 8438 FAX 516 334 5988 www ietlabs com IET LABS INC...
Страница 12: ...PRS 330 Series v Table of Contents Page left intensionally blank...
Страница 18: ...SPECIFICATIONS PRS 330 Series 6 Page left intensionally blank...
Страница 34: ...OPERATION PRS 330 Series 22 Page left intensionally blank...
Страница 36: ...USB INTERFACE PRS 330 Series 24 Page left intensionally blank...
Страница 44: ...PRS 330 Series ETHERNET INTERFACE OPTION 32...
Страница 48: ...PROGRAMMING PRS 330 Series 36 Page left intensionally blank...
Страница 67: ...PRS 330 Series APPENDIX B 55...