IET Labs HARS-LX Скачать руководство пользователя страница 10

4

HARS-LX Series

4

Specifications

Figure 2-1:

 T

ypical Operating Guide Affix

ed to Unit (See label on y

our specific unit f

or actual specifcations)

HARS-LX-5-100  OPERA

TING GUIDE

CONSUL

T INSTR

UCTION MANU

AL FOR PR

OPER INSTR

UMENT OPERA

TION

HARS-LX-5-100 lb

l/5/6/2015

W

ARNING

Obser

ve 

all 

saf

ety 

 r

ules 

when 

w

or

king 

with 

high 

voltages 

or 

line 

voltages

. Connect 

the 

(GND) 

ter

minal 

to 

ear

th 

ground 

in 

order 

to 

maintain 

the 

case 

 at 

saf

voltage

. Whene

ver 

hazardous 

voltages 

(>45 

V) 

are 

used, 

tak

all 

mea

-

sures to a

void accidental contact with an

y liv

e components:

 a) Use maxim

um insulation and minimiz

e the use of bare conductors

.  b) Remo

ve po

w

er when adjusting s

witches

.  c) P

ost w

ar

ning signs and k

eep personnel saf

ely a

w

ay

.

IET LABS, INC.

  

www

.ietlabs.com

CA

GE CODE:

 62015

• Long Island, NY   •   Email:

 inf

o@ietlabs

.com

• T

el:

 (516) 334-5959   •   800-899-8438   •   F

ax:

 (516) 334-5988

Accuracy:

±(20 ppm+0.5 mΩ)

*At 23°C “true ohm” measurement, 30-70% RH

, absolute reading

No zero subtraction required

Minimum resistance:

100 Ω ± 0.5 mΩ; determined by the lowest settable position, “1”

of the 100 Ω/step decade

Resistance repeatability:

Better than 100 µΩ

, short-term, average value

Environmental Conditions:

Operating T

emperature: 0°C to 55°C

 

Storage T

emperature: -40°C to 70°C

Switch T

ype:

Multiple solid silver contacts; dust-tight diallyl-phthalate bo

dy

.

 

To allow continuous rotation, a blank position is added on 

most decades.

For Best Performance:

Whenever the unit has been idle, turn each switch 7-10 times bo

th 

ways before using.  

This switch "break-in" procedure is standard 

metrology practice required for best accuracy to remove any sil

ver 

oxide film on the contact surfaces, typically <1 mΩ

.

Terminals:

Four

, 5-way

, gold-plated, tellurium-copper binding posts with 

low thermal emf and low resistance, for four-terminal Kelvin 

measurements, plus one binding post connected to case for 

shielding.  Rear outputs are available as an option.

MODEL:

  

HARS-LX-5-100

 

 

SN:

 D5-

1422571

Resistance 

per step

Total decade 

resistance

Max current

Max po

wer

Temperature 

coefficient 

(±ppm/ºC)

P

ower 

coefficient 

(±ppm/mW)

Stability

(±ppm/yr)

Decade positions

whic

he

ver applies fir

st

100 

Ω

1 k

Ω

0.1 A

W

3

0.1

20 ppm+0.5 m

Ω

10 positions 

“1”-”10”

 

(100 

Ω

 minim

um reading)

1 k

Ω

10 k

Ω

33 mA

W

3

0.1

10 ppm

(<5 ppm typical)

11 positions 

“0”-”10”

10 k

Ω

100 k

Ω

10 mA

W

3

0.1

100 k

Ω

1 M

Ω

3 mA

W

3

0.1

1 M

Ω

11 M

Ω

1 mA

1,500 

V peak

3

0.1

12 positions 

“0”-”11”

Wiring and s

witc

h resistance

NA

50 µ

Ω

/ºC

0.2 µ

Ω

/W

NA

Содержание HARS-LX

Страница 1: ...ietlabs com TEL 516 334 5959 FAX 516 334 5988 www ietlabs com IET LABS INC HARS LX Laboratory Standard Decade Resistance Substituter User and Service Manual Copyright 2014 IET Labs Inc Visit www ietla...

Страница 2: ...PRECISION INSTRUMENTS FOR TEST AND MEASUREMENT Email info ietlabs com TEL 516 334 5959 FAX 516 334 5988 www ietlabs com IET LABS INC...

Страница 3: ...t no charge when returned to IET Changes in this product not approved by IET or application of voltages or currents greater than those allowed by the specifications shall void this warranty IET shall...

Страница 4: ...USED TAKE ALL MEASURES TO AVOID ACCIDENTAL CONTACT WITH ANY LIVE COMPONENTS USE MAXIMUM INSULATION AND MINIMIZE THE USE OF BARE CONDUCTORS WHEN USING THIS INSTRUMENT Use extreme caution when working w...

Страница 5: ...1 Thermal emf Considerations 5 4 4 Dial Setting 6 4 5 Power Considerations 6 4 6 Environmental Conditions 6 4 7 Switch Conditioning 6 4 8 Meter Shunt Applications 7 4 9 Kelvin Bridge Applications 7 C...

Страница 6: ...tituter 1 Figure 2 1 Typical Operating Guide Affixed to Unit 3 Figure 4 1 Kelvin Bridge Connections 7 Table 5 1 Trimming Potentiometers 11 Figure 5 1 Typical Trimmer Board 11 Table 5 2 Replaceable Par...

Страница 7: ...y feature solid silver alloy contacts and quadruple leaf silver alloy wipers which keep switch contact resis tance to under 1 m per decade and more impor tantly keep switch contact resistance reproduc...

Страница 8: ...ermetically sealed low inductance Terminals Four 5 way gold plated tellutium copperbinding posts with low thermal emf and low resistance for four terminal Kelvin measurements plus one binding post con...

Страница 9: ...00 1 211 0 M 4 100 100 HARS LX 4 1k 12 110 M 4 1 k 1 k HARS LX 4 10k 121 10 M 4 10 k none HARS LX 5 0 001 121 110 5 1 m HARS LX 5 0 01 1 111 10 k 5 10 m 10 m HARS LX 5 0 1 11 111 0 k 5 100 m 100 m HAR...

Страница 10: ...100 short term average value Environmental Conditions Operating Temperature 0 C to 55 C Storage Temperature 40 C to 70 C Switch Type Multiple solid silver contacts dust tight diallyl phthalate body To...

Страница 11: ...tandard temperatures near 23 C 3 3 Repackaging for Shipment If the instrument is to be returned to IET Labs contact the Service Department at the number or address shown on the front cover of this man...

Страница 12: ...low resistance increments are important care must be taken in connecting to the terminals of the decade box In particular to keep contact resistance to a mini mum 4 terminal connections should be empl...

Страница 13: ...0 Since the highest decade has an additional 11 po sition resistance values of over 1 2 times nominal maximum value can be obtained 4 5 Power Considerations To maintain the maximum possible accuracy a...

Страница 14: ...resistance standard for all Kelvin bridge measurements When connected as shown in Figure 4 1 errors caused by lead and contact resis tances can be made negligible because they appear as part of the ge...

Страница 15: ...igure 4 1 Figure 4 1 Rheostat Dial In order to eliminate contact resistance and thermal emf the HARS LX integrates the rheostat as shown in Figure 4 2 This way the wiper is in the low potential circui...

Страница 16: ...from the side of the instrument and remove the housing 2 Remove any dust or debris using optical grade dry compressed air or a clean brush 3 Replace the housing and reattach the 4 hous ing screws The...

Страница 17: ...he follow ing models HATS LR HATS Y SRL Series The 1 and 10 transfer standards are optional and are only used to take advan tage if desired of the adjustability of these two decades Precision resistan...

Страница 18: ...trim or adjust any resistances proceed as follows 1 Stabilize HARS LX at laboratory tempera ture of 23 C for at least 8 hours 2 Remove the 4 housing screws from the sides of the instrument and remove...

Страница 19: ...Designation All decades but 1 k Potentiometer Designation 1 k decade 1 T0 T1 2 T1 T2 3 T2 T3 4 T3 T4 5 T4 T5 6 T5 T6 7 T6 T7 8 T7 T8 9 T8 T9 10 T9 T10 11 T10 1 M steps only Table 5 1 Trimming Potenti...

Страница 20: ...y Not Shown HARS 4000 LX 0 1 100 m step Decade Switch Assembly Not Shown HARS 4000 LX 1 1 step Decade Switch Assembly Not Shown HARS 4000 LX 10 10 step Decade Switch Assembly Not Shown HARS 4000 LX 10...

Страница 21: ......

Страница 22: ......

Отзывы: