IES PR-6 Скачать руководство пользователя страница 6

IES PR-6 dimmer pack Operators’ Manual v. 1.1         25-04-2002 6 

programmed together, depending on whether the 
dimmer set-up has been set to ‘SINGLE or ‘JOINED’ 
(see paragraph 6.4.1). If the configuration is set to 
single, a number is shown in each relevant channel 
reference [4], and if all dimmers are programmed 
together, a T is shown in square brackets [T]. Note 
that if T is activated, an underscore bar is added, 
making it appear as an ‘

I

’. 

6.3 Front Panel Controls 

All of the performance and control characteristics, 
measurements and status reports, are available 
from the front panel controls and LCD screen. When 
power is applied and the RCD is switched on, the 
power LED will illuminate. The DMX LED will 
illuminate if a valid DMX signal is present. 
 
During the power-up reset process, the LCD display 
shows identification details and the software version 
before displaying the output screen: 

L: 

3;33;

_ D:001? 

CH:123456 A:032v 

This display shows the channel levels (bargraphs at 
the top left), the DMX address of the first channel in 
the PR-6 dimmer pack (D:xxx) and the DimSTAT 
address of the unit (A:xxx). The number of 
bargraphs shown relates to the number of dimmers 
in the PR-6 dimmer pack – either 2, 4 or 6.  

Note: A questionmark (?) adjacent to the DMX 

address shows the DMX signal is not 
valid, and the ‘v’ adjacent to the DimSTAT 
address number indicates communication 
is active. 

6.4 General controls  

PR-6 dimmer packs have the capacity to store 
performance characteristics individually for each 
dimmer or combined for all dimmers in the group. 
This feature is independent of the choice of DMX 
numbering scheme, thus the dimmers may have 
individual characteristics, but with consecutive DMX 
addresses. 

6.4.1 To change the dimmer characteristic set-up 

scheme: 

1.  Press INST. 

2.  Press 

ê

 or 

é

 to choose GENERAL 

SETTINGS menu.  
Press ENT. 

3. Press 

ê

 or 

é

 to choose CONFIG 

CHANNEL menu.  
Press ENT. 

4.  The screen shows: 

GENERAL  

CH_CONF. [SINGLE] 

5.  Use 

é

 or 

ê

 to select either SINGLE (for 

different individual channel parameters) or 
JOINED (if all dimmers have the same 
characteristics). 

6.  Press ENT (to record the changes) or 

EXIT (to leave the previous settings 
unchanged, and return to the home page). 

6.5 DMX programming 

Each dimmer in the PR-6 dimmer pack is assigned a 
DMX channel number. A feature is provided to set 
sequential number groups (‘joined’ addressing) 
instead of individual settings (‘single’ addressing). 
When programming a dimmer, IT IS IMPORTANT 
TO SET THE DMX ADDRESSING SCHEME 
BEFORE the individual characteristics are set, as a 
later change can reset previously recorded individual 
channel characteristic settings. 

6.5.1 To set up DMX addressing scheme: 

1.  Press INST. 

2.  Press 

ê

 or 

é

 to choose GENERAL 

SETTINGS menu.  
Press ENT. 

3. Press 

ê

 or 

é

 to choose DMX ADDRESS 

menu.  
Press ENT. 

4.  The screen shows: 

GENERAL  

DMX MODE [SINGLE] 

5.  Use 

é

 or 

ê

 to select either SINGLE (for 

different individual DMX addresses) or 
JOINED (if the dimmers are numbered 
sequentially from the start address). 

6.  Press ENT (to record the changes) or 

EXIT (to leave the previous settings 
unchanged, and return to the home page). 

6.5.2 To set-up DMX addresses: 

1.  First set the DMX scheme as described 

above (either individual or start address). 

2.  Press DMX, and the screen displays: 

DMX: [001] 002 

CHAN.: 1 2 

3.  If SINGLE has been selected, two 

channels are displayed at a time, with their 
relevant DMX address. Use 

é

 and 

ê

 to 

select the address needed for the first 
dimmer channel and move to other 
channels by pressing 

ç

 and 

è

 and 

continue adjusting each DMX address by 
pressing 

é

 and 

ê

 as before.  

4. If JOINED has been selected, only one 

DMX number line is entered which is the 

Содержание PR-6

Страница 1: ...orting 4 4 7 Backup settings 4 5 Information displays and manual control 4 5 1 To check dimmer performance 4 5 2 To check software versions 4 5 3 To manually control a dimmer level 5 5 4 To operate the chaser 5 6 Programming 5 6 1 Flow diagram 5 6 2 General Programming Advice 5 6 3 Front Panel Controls 6 6 4 General controls 6 6 5 DMX programming 6 6 6 Serial address 7 6 7 Maximum Minimum levels 8...

Страница 2: ...for 19 equipment enclosures and accommodates 3U of panel space 2 3 Connections Note All electrical connections to the PR 6 dimmer pack must be made by a suitably qualified person 2 3 1 Power input connections Input power is supplied via a 3 phase neutral and earth 4mm2 flexible cable or a 4 wire delta supply cable For ease of installation and removal a suitable plug and socket such as a 32A three ...

Страница 3: ...guration individual or combined Channel configuration individual or combined Sleep mode Minimum level reset preheat off when DMX is not present Factory reset Channel information Password set up Dimmer hardware configuration CHAS with LED CHASe Provides set up for the dimmer s internal chase system for stand alone display effects The LED illuminates when the dimmer is in the chase mode CONF CONFigu...

Страница 4: ...ing All IES dimmers incorporate a bi directional communications system called DimSTAT which provides feedback of the dimmer status and fault reporting to a PC DimSTAT also enables a remote PC to control any dimmer in the network and to update the dimmer s internal operating software and preset options DimSTAT network software and a remote PC are optional extras 4 7 Backup settings Should the DMX s...

Страница 5: ...g FADE 5 Press ENT to start the chase and the screen shows e g CH 3_3_3_ AUTO 05 01 1 0 3 OFF 6 The step number will increment as the chase progresses restarting at 1 at the end of each cycle 7 With the chase number underlined press é or ê to switch to another chase pattern 6 Programming 6 1 Flow diagram An overview of the flow chart showing the menu structure and options is shown in section 11 6 ...

Страница 6: ... the dimmer characteristic set up scheme 1 Press INST 2 Press ê or é to choose GENERAL SETTINGS menu Press ENT 3 Press ê or é to choose CONFIG CHANNEL menu Press ENT 4 The screen shows GENERAL CH_CONF SINGLE 5 Use é or ê to select either SINGLE for different individual channel parameters or JOINED if all dimmers have the same characteristics 6 Press ENT to record the changes or EXIT to leave the p...

Страница 7: ...l number is underlined or T if all channels are to be set together 5 Press é or ê to adjust the backup level The dimmer output is live while the backup levels are adjusted 6 Press ENT to leave the menu and record the changes or EXIT to leave the previous settings unchanged 6 5 5 To set up a DMX Minimum reset In order to increase the flashing speed of higher wattage lamps it is sometimes necessary ...

Страница 8: ... channel number or T if the dimmer set up scheme copies characteristics to all dimmers in the rack and gives access to all configuration options CONFIG CH 1 MAX 100 2 Press é or ê to select the required dimmer number 3 Press è to select the maximum or minimum option and to highlight the recorded value in square brackets CONFIG CH 1 MIN 00 0 Setting options are MIN minimum level from 00 to 29 9 MAX...

Страница 9: ...and record the changes or EXIT to leave the previous settings unchanged 6 10 Non Dim operation PR 6 dimmer packs may be set to switch on and off rather than dim and in this way are used for many other functions such as switching power to working lights non dim and auxiliary circuits There are two methods of selecting non dim operation as described here and also as one of the Dimmer Curves as descr...

Страница 10: ... to leave the menu and record the changes or EXIT to leave the previous settings unchanged 6 12 Passwords Passwords are used at 3 levels of the PR 6 dimmer pack dimmer set up procedure DMX CONF and INST One password or 3 separate passwords may be used to give a range of access options Passwords are in the form of 4 digit codes and may be set and used from the front panel of the dimmer and DimSTAT ...

Страница 11: ... as follows 6 14 1 To check fault reports and to reset the log 1 Press CHK Note This screen never requires a password 2 The screen shows ERR STATUS CH 01 TEMP 04 where 04 is the short circuit error code and 01 is the affected dimmer circuit within the module 3 Press ê or é to view any other reports in the error log 4 Press ENT to leave the menu and CLEAR the log or EXIT to leave the log unchanged ...

Страница 12: ... at full load 8 2 First line maintenance This check list provides initial assistance in the case of a problem which has not been identified and reported by the dimmer s own software 8 2 1 LCD display blank Check all power supply connections Check module s RCBO or MCB is on 8 2 2 LCD display corrupted Switch off and on again If the fault persists open the module and check all connections and that p...

Страница 13: ...E17 Schuko French product ref PR 6 C PR 6 S PR 6 F Control connectors in and out XLR 5 DMX data pins 2 3 DimSTAT data pins 4 5 control data Control signal DMX 512 4 wire DMX and DimSTAT bi directional data Max level preset 30 0 100 full Min level preset 0 0 29 9 Response time 0 00 secs 9 9 secs up and dn Local control LCD screen cursor controls to access all functions and status Passwords 3 passwo...

Страница 14: ...lares that the product Product name PR6 Model number PR6 no 9908 2005 9913 2001 Conforms to the following product Specifications Emission EN 50081 1 EN 50081 2 EN 55011 EN 55014 Immunity EN 50082 1 EN 50082 2 EN 55024 2 6 kV Contact discharge 8 kV Air discharge EN 55024 3 3 V m EN 55024 4 1 kV Signal lines 2 kV Power lines Supplementary information The product complies with the EMC Directive 89 33...

Страница 15: ...IES PR 6 dimmer pack Operators Manual v 1 1 25 04 2002 15 11 Menu flow chart ...

Страница 16: ...ol 5 manual control 5 DimSTAT 12 fault finding 12 DMX front panel control button 3 DMX address setup 6 DMX addressing scheme 6 DMX backup condition setup 7 DMX backup preset setup 7 DMX booster isolator 2 DMX data signals 2 DMX LED 3 DMX Minimum reset setup 7 DMX network 2 DMX programming 1 6 DMX termination 2 E ENT cursor arrows 3 errors reported codes 11 EXIT front panel control 3 F Factory defa...

Страница 17: ...non dim switch setup 9 O ON LED 3 output fault finding 12 Over temperature error message 12 P Passwords 1 5 10 setup 10 Pin connections 2 Positioning 1 2 Power connections 2 Product range 1 2 Programming 1 5 Programming Advice 1 5 PROPortional mode defined 10 R RCBO fault finding 12 RCD fault finding 12 Reset factory defaults 11 Response speed defined 1 4 Response time 1 8 response times setup 8 S...

Отзывы: