1.  Safety notes

Notice

Read these instructions carefully, and look at the equipment to become familiar with the device before trying 

to install, operate, or maintain it. The following special messages may appear throughout this documentation 

or on the equipment to warn of potential hazards or to call attention to information that clarifies or simplifies 

a procedure.

The addition of this symbol to a Danger hazard statements indicates that an electrical hazard 

exists, wich result in personal injury if the instructions are not followed.

This is the safety alert symbol. It is used to alert you to potential personnal injury hazards. Obey 

all safety messages that follow this symbol to avoid possible injury or death.

 

I

DANGER

DANGER

 indicates an imminently hazardous situation which, if not avoided, 

will result

 in death or seri-

ous injury.

 

I

WARNING

WARNING

 indicates a potentially hazardous situation which, if not avoided, 

can result

 in death or seri-

ous injury.

 

I

CAUTION

CAUTION

 indicates a potentially hazardous situation which, if not avoided, 

can result

 in minor or mod-

erate injury.

NOTICE

NOTICE

 is used to address practices not related to physical injury.

Please note

No responsibility is assumed by IES Synergy for any consequences arising out of the use of this material.

Содержание Keywatt 50 Series

Страница 1: ...User Manual Keywatt 50 Station Bus www ies synergy com DUM017749 EN_V001b...

Страница 2: ...our own personal noncommercial use all or part of this document on any medium whatsoever without permission of IES Synergy given in writing You also agree not to establish any hypertext links to this...

Страница 3: ...eral Safety instructions 6 4 Overview 7 External view 7 5 Specification 8 Main supply 8 3 phase L1 L2 L3 N GND 3x400VAC 8 Technical specification 8 Compliance 10 Derating 10 6 Utilization 12 Human Mac...

Страница 4: ...tions are not followed This is the safety alert symbol It is used to alert you to potential personnal injury hazards Obey all safety messages that follow this symbol to avoid possible injury or death...

Страница 5: ...aims to provide informations needed for the use of the Keywatt 50 Station Bus This guide must be read with other related documents This guide is intended for users of the charging stations Document s...

Страница 6: ...racked opened or show any other indication of damage Replace the damaged cables by same caracteristics cables Do not use a cord extension set second cable assembly or adaptors in addition to the cable...

Страница 7: ...GOING CHARGE ENDED WARNING ERROR START STOP Position Description Lifting rings Touch screen Connector holster in option State of charge Door lock RJ45 input for maintenance only Power button START STO...

Страница 8: ...sh current limitation per phase IINRUSH LIMIT 3 x IAC Max Rated current circuit breaker IBREAK Rating 100A typ Rated short circuit capacity IBREAK Capacity 15 kA Max Max earth leakage current ILEAKAGE...

Страница 9: ...ic level 1m all directions Db A 58 9 dbA 1m Climatic Environment constraints Operating temperature with derating 25 C to 50 C 3 Storage temperature 25 C to 70 C Relative humidity RH 5 to 95 Installati...

Страница 10: ...vehicle for control of DC charging in the Combined Charging System DIN 70121 Vibration and shock resistance STD ASTM D 4169 16 STD ASTM D 880 92 STD ASTM D 4728 17 STD ASTM D 6055 96 STD ASTM D 6179 0...

Страница 11: ...www ies synergy com User Manual DUM017749 EN 11...

Страница 12: ...achine interface HMI Lights Charger ready CCS connected Charging Charge ended Warning Error Start a charge session Before starting a charge session ensure the unit is properly assembled in accordance...

Страница 13: ...with the electrical vehicle to collect information All these steps are necessary to adapt the charging station parameters to the EV EV charge While the EV is charging the charging station shows the in...

Страница 14: ...Emergency Stop In the event of an emergency the Emergency Stop button may be pressed to instantly stop charging To emergency stop follow these steps 1 Press the emergency stop button bellow the charg...

Страница 15: ...our vehicle when plugging until the charge has started Please un plug your vehicle Error occurred 0x3A Your battery model is incompatible with this char ger Please unplug your vehicle Your battery mod...

Страница 16: ...the following messages are displayed on the charging station s screen the charge is unavailable Message Description Charger inoperative Cannot charge here Charger inoperative Backend server request ch...

Страница 17: ...intenance work to ensure that it is separated from the supply of AC mains Failure to do so may cause physical injury or damage to the electrical system and charging unit Maintenance of the charging st...

Страница 18: ...www ies synergy com User Manual DUM017749 EN 18 Notes...

Страница 19: ...www ies synergy com User Manual DUM017749 EN 19 Notes...

Страница 20: ...ine Bergfeldstr 11 34130 Saint Aun s 83607 Holzkirchen France Germany Tel 33 0 4 99 13 62 80 Tel 49 0 80244633980 Fax 33 0 4 99 13 62 81 IES Synergy Inc USA IES WANMA New Energy China 330 East Maple R...

Отзывы: