IEI Technology SSW-iLW Скачать руководство пользователя страница 2

www.ieib.com 

Page 2 of 13 

6050723  Rev 1.0 

 

SSiLW  (

ILLUMINATED WEATHER RESISTANT) 

Installation Manual

 

 
Features: 

 

Vandal resistant metal case 

 

Illuminated Backlit Hardened Keys 

 

Heavy Traffic Application 

 

Flush Mount  

 

Indoor / outdoor Applications 

 

Fully encapsulated 

 

Installation: 

 

Section 1:  Unpacking and checking the packing list.

 

 

Section 2:  Mounting the SSiLW.

 

 

Section 3:  Wiring the SSiLW. 

 

a)  To an IEI controller. 
b)  To Wiegand controller. 
c)  Wiring the IEI controller.    

• 

To electromagnetic door lock 

• 

To integrated electromagnetic door lock 

• 

To door srtike 

• 

To integrated  door strike 

 

 

 

Section 4:  Programming

 

 

Section 5:  Troubleshooting.

 

 

Page 12:   Warranty 

 

Page 13:  Template 

 

 

Section 1:  Unpacking and checking the packing list

 

Open the box, and inside you will find:  
 

 

SSiLW keypad  

6 Conductor wire harness 

1 1/4" black, socket cap flat head machine screws 

1 1/4" black, Phillips flat head sheet metal screws 

1 11/64" 

Allen 

wrench 

Installation Manual for SSiLW 

 

Also Included when using model: 212  SiL  
 

• 

Programming controller 

• 

Four conductor wire harness (1) 

• 

Three conductor wire harness(4) 

• 

Command and control features and programming guide 

 

Also Included when using model: 232  SiL  

             

• 

Programming controller 

• 

Four conductor wire harness(1) 

• 

Three conductor wire harness(4) 

• 

Self contained access control features and programming guide 

              

Please check the contents of this package and verify all components in the packing list are 
present

.  

Taking this inventory  will familiarize you with the components as well as ensure that 

you have a complete parts list. 

International Electronics, Inc. 
427 Turnpike Street 
Canton, Massachusetts 02021 

Содержание SSW-iLW

Страница 1: ...www ieib com Page 1 of 13 6050723 Rev 1 0 Open Technology SSW iLW ...

Страница 2: ...st Open the box and inside you will find 1 SSiLW keypad 1 6 Conductor wire harness 2 1 1 4 black socket cap flat head machine screws 2 1 1 4 black Phillips flat head sheet metal screws 1 11 64 Allen wrench 1 Installation Manual for SSiLW Also Included when using model 212 SiL Programming controller Four conductor wire harness 1 Three conductor wire harness 4 Command and control features and progra...

Страница 3: ... 3 8 x 5 1 8 x 5 8 Wiring the design series SSiLW to an IEI controller requires a 4 conductor stranded shielded cable between the keypad and controller Maximum distance between the two are as follows 22 AWG stranded 250 feet 20 AWG stranded 500 feet 18 AWG stranded 1000 feet At the controller connect the four conductor wire harness to the four pin connector labeled p2 on the controllers relay boar...

Страница 4: ... loop common W O Door position input W Timed egress BR Note 1 If no door contact is being used it must be jumped closed White Orange White NO C NC NO C NC NO C NC NC C NO Magnetic door lock Fail safe Forced door Door ajar functions require a normally closed set of door contacts Note 2 If powering the keypad and lock with same power supply as shown in diagram lock voltage must match power supply vo...

Страница 5: ...itch Forced door Door ajar functions require a normally closed set of door contacts Note 1 If door contact is not being used the white with orange stripe and the white wire should be spliced together Note 2 If power keypad and lock with same power source the lock voltage must match the power supply voltage SW1 Normally closed door contacts To alarm panel Closed loop V V Siren Sounder NC C NO 3 2 1...

Страница 6: ...Door position input W Timed egress BR NO C NC NO C NC NO C NC Programming switch Forced door Door ajar functions require a normally closed set of door contacts 3 2 1 Part EZ REX Electric door strike fail secure White Orange W O White W Brown BR W O W BR PWR SW1 P5 Note 1 If door contact is not being used the white with orange stripe and the white wire should be spliced together Note 2 If power key...

Страница 7: ...NO C NC Programming switch Electric door strike fail secure Forced door Door ajar functions require a normally closed set of door contacts SW1 Normally closed door contacts To alarm panel Closed loop V V Siren Sounder NC C NO 3 2 1 Part EZ REX White Orange W O White W Brown BR W O W BR PWR Note 1 If door contact is not being used the white with orange stripe and the white wire should be spliced to...

Страница 8: ...ed Series Press 91 3 0 Secured Series Recording status OUT Press 91 4 1 Secured Series Recording Status IN Press 91 4 0 Below for SS iLW Only Wiegand Red led enable Press 91 5 1 Wiegand Red led disable Press 91 5 0 Wiegand Red led state High Press 91 6 1 Wiegand Red led state Low Press 91 6 0 Wiegand Green led enable Press 91 7 1 Wiegand Green led disable Press 91 7 0 Wiegand Green led state High ...

Страница 9: ...commended that you perform the self test mode While the unit is powered up enter the following on the SSiLW keypad 7890 123456 If all 12 key presses have been verified the keypad will enter self test mode The LED s will alternate three times and the sounder will beep three times followed by a flickering yellow LED Press any key to return to normal operation System Defaults The SS iLW series keypad...

Страница 10: ...r code by press 1 New Master Code Repeat Master Code When finished with programming power down the unit separate the blue and brown wires from the white yellow on the SSiLW harness and power back up The keypad is now ready to use Situation 2 No LED s are lit on the keypad Reason Power is not reaching the keypad Solution With a meter check the voltage connection at the SSiLW keypad on the Red Black...

Страница 11: ...Series and sets it in Hub Front End mode Red 5 12 VDC Black GND Wht Blk Wht Yel Blue Brown Defaults Design Series and sets it in Wiegand 26 bit mode Red 5 12 VDC Black GND Wht Blk DAO Wht Yel DA1 Blue LED1 Brown Not used If the local program code is lost or forgotten power down the system connect the wire harness as shown below then power the system up Change your local program code then power dow...

Страница 12: ... to IEI s facility freight and insurance charges prepaid after obtaining IEI s Return Merchandise Authorization IEI WILL not be liable to the purchaser or any one else for incidental or consequential damages arising from any defect in or malfunction of it s products This warranty shall expire two years from mfg date code found on micro processor for Door Gard Keypads Except as stated above IEI mak...

Страница 13: ...www ieib com Page 13 of 13 6050723 Rev 1 0 Note Use this template to help d rill holes for easy installation Weep holes ...

Отзывы: