ICE-BDE-T7 COM Express Module
Page 85
NOTE:
When exiting a program it is necessary to disable the Watchdog Timer,
otherwise the system resets.
EXAMPLE PROGRAM:
; INITIAL TIMER PERIOD COUNTER
;
W_LOOP:
;
MOV
AX, 6F02H
;setting the time-out value
MOV
BL, 30
;time-out value is 48 seconds
INT
15H
;
; ADD THE APPLICATION PROGRAM HERE
;
CMP
EXIT_AP, 1
;is the application over?
JNE
W_LOOP
;No, restart the application
MOV
AX, 6F02H
;disable Watchdog Timer
MOV
BL, 0
;
INT
15H
;
; EXIT ;
Содержание ICE-BDE-T7
Страница 11: ...ICE BDE T7 COM Express Module Page 1 Chapter 1 1 Introduction...
Страница 19: ...ICE BDE T7 COM Express Module Page 9 Chapter 2 2 Packing List...
Страница 23: ...ICE BDE T7 COM Express Module Page 13 Chapter 3 3 Connectors...
Страница 40: ...ICE BDE T7 COM Express Module Page 30 Chapter 4 4 Installation...
Страница 46: ...ICE BDE T7 COM Express Module Page 36 Chapter 5 5 BIOS...
Страница 81: ...ICE BDE T7 COM Express Module Page 71 6 Software Drivers Chapter 6...
Страница 83: ...ICE BDE T7 COM Express Module Page 73 Appendix A A Regulatory Compliance...
Страница 85: ...ICE BDE T7 COM Express Module Page 75 B Product Disposal Appendix B...
Страница 87: ...ICE BDE T7 COM Express Module Page 77 Appendix C C BIOS Options...
Страница 90: ...ICE BDE T7 COM Express Module Page 80 Appendix D D Digital I O Interface...
Страница 93: ...ICE BDE T7 COM Express Module Page 83 Appendix E E Watchdog Timer...
Страница 96: ...ICE BDE T7 COM Express Module Page 86 Appendix F F Hazardous Materials Disclosure...