IBX-700 Integrated Service Computer
Page 30
Jumper Settings:
See
Jumper Location:
See
The FSB Select jumper specifies the front side bus (FSB) as 400 MHz or 533 MHz. FSB
Select jumper settings are shown in
FSB Select
Description
Short 1-2
400 MHz
Default
Short 2-3
533 MHz
Table 3-6: FSB Select Jumper Settings
The location of the FSB Select jumper is shown in
below.
Figure 3-4: FSB Select Jumper Location
3.3.3 Clear CMOS Jumper
Jumper Label:
CLR_CMOS1
Jumper Type:
3-pin header
Jumper Settings:
See
Jumper Location:
See
Содержание IBX-700 Series
Страница 1: ...IBX 700 Integrated Service Computer Page i IBX 700 Series Integrated Service Computer ...
Страница 18: ...IBX 700 Integrated Service Computer Page xviii THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Страница 19: ...IBX 700 Integrated Service Computer Page 1 1 Introduction Chapter 1 ...
Страница 30: ...IBX 700 Integrated Service Computer Page 12 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Страница 31: ...IBX 700 Integrated Service Computer Page 13 2 Mechanical Description Chapter 2 ...
Страница 37: ...IBX 700 Integrated Service Computer Page 19 3 System Components Chapter 3 ...
Страница 53: ...IBX 700 Integrated Service Computer Page 35 4 Installation Chapter 4 ...
Страница 59: ...IBX 700 Integrated Service Computer Page 41 5 AMI BIOS Chapter 5 ...
Страница 103: ...IBX 700 Integrated Service Computer Page 85 6 Driver Installation Chapter 6 ...
Страница 122: ...IBX 700 Integrated Service Computer Page 104 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Страница 123: ...IBX 700 Integrated Service Computer Page 105 7 Software Application iSMM Chapter 7 ...
Страница 139: ...IBX 700 Integrated Service Computer Page 121 8 Troubleshooting and Maintenance Chapter 8 ...
Страница 157: ...IBX 700 Integrated Service Computer Page 139 A Safety Precautions Appendix A ...
Страница 161: ...IBX 700 Integrated Service Computer Page 143 B Interface Connectors Appendix B ...
Страница 168: ...IBX 700 Integrated Service Computer Page 150 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Страница 169: ...IBX 700 Integrated Service Computer Page 151 C BIOS Menu Options Appendix C ...
Страница 173: ...IBX 700 Integrated Service Computer Page 155 D Watchdog Timer Appendix D ...
Страница 176: ...IBX 700 Integrated Service Computer Page 158 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Страница 177: ...IBX 700 Integrated Service Computer Page 159 E Address Mapping Appendix E ...
Страница 180: ...IBX 700 Integrated Service Computer Page 162 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Страница 181: ...IBX 700 Integrated Service Computer Page 163 F Hazardous Materials Disclosure Appendix F ...
Страница 185: ...IBX 700 Integrated Service Computer Page 167 G JMicron RAID Appendix G ...
Страница 214: ...IBX 700 Integrated Service Computer Page 196 THIS PAGE IS INTENTIONALLY LEFT BLANK ...
Страница 215: ...IBX 700 Integrated Service Computer Page 197 9 Index ...