Wiring and powering inputs
Wiring temperature sensors
NOTE
: IEI temperature sensors can be located up to 500 feet from the MicroNode using CAT5
twisted pair cable. The black wire from the sensor is the ground.
4
April 13, 2009
Страница 1: ... Power Supply The MicroNode requires 12 VDC 2 Amp power supply With external power supply no PoE is needed The power supply must be located no further than 50 feet from the MicroNode RJ 45 network connector 12 VDC input RJ 45 network connector 12 VDC input Bottom Board topside Bottom Board Underside NOTE PoE total power available for external 12V output is 500 mA 6 watts NOTE 12VDC power supply to...
Страница 2: ... D1 D0 Grn LED Bpr Reader connectors on the Top board Wiring and powering 12VDC door strikes and maglocks Any output can be used for powering 12V strikes or maglocks If output 1 or 3 is selected you must set the strike switch in the NORM position Wires must be a minimum of 20 AWG 2 April 13 2009 ...
Страница 3: ... Polarity shown must be observed if using a diode to clamp the kickback voltage from the strikes IEI recommends the use of a diode varistor or transient voltage suppressor TVS Wiring outputs not requiring MicroNode power outputs 4 3 2 1 Strike switch for output 1 in NORM position NO NC common NO common NC CAUTION If output 1 or 3 is selected you must set the strike switch in the NORM position Othe...
Страница 4: ... powering inputs Wiring temperature sensors NOTE IEI temperature sensors can be located up to 500 feet from the MicroNode using CAT5 twisted pair cable The black wire from the sensor is the ground 4 April 13 2009 ...