3.7

Self–test

The serial input display module can be operated independently from the host by using the "Self–test" option.

1.  Check the multiplex jumper for proper setting (Section 4.2).

2.  Connect a +5V power supply and potentiometer as discussed in Paragraph 2.1 and Figure 1.

3.  Momentarily short the self–test line to GND (P2 pin 5 to pin 8).

4.  All character positions should display the character "H".

5.  The module can be stepped through the remaining test display frames by using the self–test line as

in Step 3 (above).  The display will advance from frame to frame each time the self–test line is
momentarily shorted to ground.  The remaining frames display: I, #, all pixels on, jumper settings in
HEX (with jumper #8 being the LSB, see Section 4.2), firmware version number, and then
resumption of normal operation.

6.  Upon completion of "Self–test", the module is returned to the normal mode of operation with its

previous controller and data/instruction (RS bit) settings.

3.8

Diagnostics

1.  The display module can be operated by the host in a HEX dump mode.  This diagnostic mode

provides for the HEX display of all serial data received.  While operating in this mode, the module will
ignore the multiplex jumper setting and operate the display in a 1/8 multiplex mode.

2.  Check the module jumpers for proper baud speed and parity settings (Section 4.2).

3.  With power "OFF" short the self–test line to GND (P2 pin 5 to pin 8).

4.  While the self–test line is shorted to ground, apply +5 Volts to the display module.  The self–test line

is now ineffective and may be allowed to float.

5.  All serial data received will now be displayed in HEX.  To return to the normal operating mode,

remove power, allow the self–test line to float, and re–apply power.

If a parity or framing error should occur, the most significant nibble of the HEX code will be displayed as:

HEX Code

Parity Error

Framing Error

0X

GX

gX

1X

HX

hX

2X

IX

iX

3X

JX

jX

4X

KX

kX

5X

LX

lX

6X

MX

mX

7X

NX

nX

8X

OX

oX

9X

PX

pX

AX

QX

qX

BX

RX

rX

CX

SX

sX

DX

TX

tX

EX

UX

uX

FX

VX

vX

X = Least significant nibble

*   Characters with parity and framing errors are displayed as framing errors only.  Framing errors can occur
due to loss of serial bit timing, improper baud rate and/or parity setting.

Содержание 03805-06-0200

Страница 1: ...HEET 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 REVISION STATUS PROJ NO 411 CONTRACT INDUSTRIAL ELECTRONIC ENGINEERS INC VAN NUYS CALIFORNIA DRAWN R January 3 19 93 SERIAL DATA INP...

Страница 2: ...M CG RAM 9 2 2 8 Parallel Serial Data Conversion Circuitry Timing Generator Circuitry 9 3 0 THEORY OF OPERATION 10 3 1 Serial Interface 10 3 2 Error Detection and Reporting 10 3 3 Power up Sequence 11...

Страница 3: ...Inc SIZE A CODE IDENT NO 05464 S03805 06 0200 Van Nuys California SCALE N A REV C SHEET 3 6 2 Non Operating 19 7 0 OPTICAL SPECIFICATIONS 19 7 1 Optical Characteristics 19 7 2 Viewing Angle Adjustment...

Страница 4: ...RAM and Character Patterns CG RAM Data 9 Figure 5 8 bit Serial Data Format 10 Figure 6 Default Configuration at Power up 11 Figure 7 Instruction Sequence 11 Figure 8 Data Sequence 11 Figure 9 Instruct...

Страница 5: ...Bi refringent Effect SBE liquid crystal cell used in this display The serial data input model of the 03805 06 Daystar Nova display allows communication between a host processor and the display by mea...

Страница 6: ...cted to the same 5 Volt supply as the display module RESET and TEST pull down to ground to activate the function All three inputs may be left open if not used The VBIAS test point is used at the facto...

Страница 7: ...eg1 Seg40 Com1 Com16 D 5 5 40 Figure 2 LCD Controller Block Diagram 2 2 1 Instruction Register IR The IR stores instruction codes such as display clear and cursor shift and address information of the...

Страница 8: ...M CG ROM The CG ROM generates character patterns of 5 X 7 dots from 8 bit character codes The 192 5 X 7 dot matrix characters are illustrated in Figure 3 Figure 3 Correspondence Between Character Code...

Страница 9: ...aracter Patterns CG RAM Data NOTES 1 The CG RAM consists of 64 bytes Any bytes not used for character pattern information can be used for general purpose data RAM The 5 6 and 7 bits are never used for...

Страница 10: ...o parity and two stop bits Since two command characters and numerous data characters are 8 bits in length it is recommended to operate in 8 bit mode if the host has this capability Where this is not p...

Страница 11: ...Jumper defined per section 4 2 Parity bit present Parity checking enable Parity Odd or Even 7 or 8 data bits Multiplex rate of LCD Display clear YES Display ON OFF ON Cursor location Position 0 Cursor...

Страница 12: ...ets DD RAM address DD RAM data is sent or received after this is set 40 s Read Busy Flag and Address BF Reads Busy Flag BF and Address Counter 0 s Write Data to CG or DD RAM Writes data into CG RAM or...

Страница 13: ...Electronic Engineers Inc SIZE A CODE IDENT NO 05464 S03805 06 0200 Van Nuys California SCALE N A REV C SHEET 13 DL 0 4 bit operation BF 1 Operating internally BF 0 Can accept instruction Figure 9 Inst...

Страница 14: ...er 1 Instruction S 12h Subsequent Data Is Controller 1 Display Data 15h Subsequent Data Is Controller 2 Instruction S 16h Subsequent Data Is Controller 2 Display Data 17h Subsequent Data Down Loads Sp...

Страница 15: ...described in Paragraph 2 2 7 the user has these additional preformatted characters available Note that all down loaded character data is lost and must be reloaded after power has been removed To faci...

Страница 16: ...Industrial Electronic Engineers Inc SIZE A CODE IDENT NO 05464 S03805 06 0200 Van Nuys California SCALE N A REV C SHEET 16 Figure 10 Down loadable Special Characters...

Страница 17: ...it settings 3 8 Diagnostics 1 The display module can be operated by the host in a HEX dump mode This diagnostic mode provides for the HEX display of all serial data received While operating in this mo...

Страница 18: ...B 1 1 E1 4800 Baud 1200 Baud 2 E2 2 x Baud 1 x Baud 3 E3 Parity No Parity 4 E4 Even Parity Odd Parity 5 E5 7 Data Bits 8 Data Bits 6 E6 1 8 Mpx N A 1 16 Mpx 7 Not Used 8 Not Used Baud rate will defaul...

Страница 19: ...e tRCC of the power supply is correct at turn on 1ms tRCC 10ms Figure 11 represents the requirements of the power supply Note that tOFF stipulates the minimum time that power can be OFF tOFF 1ms durin...

Страница 20: ...nsing Humidity 40 C Absolute humidity must be lower the humidity of 95 RH at 40 C Vibration 10g at 10 to 400Hz 3 axes Shock 10g all axes 6 2 Non Operating Temperature 40 C to 85 C 7 0 OPTICAL SPECIFIC...

Страница 21: ...0 Figure 13 Definition of Vertical Viewing Angle Definition of Horizontal Viewing Angle top Viewing Display for Bottom Viewing Displays 20 Typically X X Y Y Normal 20 90 90 Figure 14 Definition of Hor...

Страница 22: ...ard potentiometer This is considered to be a nominal adjustment but the user may prefer to vary this to optimize the viewing for a particular application The bias voltage is measured between VCC pin 7...

Страница 23: ...ed that an air gap of at least 030 to 050 minimum be provided between the window material and the surface of the LCD to prevent the transfer of static charges to the front surface of the LCD Supertwis...

Страница 24: ...strial Electronic Engineers Inc SIZE A CODE IDENT NO 05464 S03805 06 0200 Van Nuys California SCALE N A REV C SHEET 24 10 0 OUTLINE AND INSTALLATION CHARACTERISTICS Figure 17 03805 06 0200 Outline Dra...

Отзывы: