background image

5

4

PART

DESCRIPTION

QUANTITY

L

Flexible Exhaust Hose

1

M

Exhaust Nozzle Connector 

2

N

Tube Adapter

1

O

Screw

4

P

Window Panel Extension 

1

Q

Window Panel 

1

R

Drain hose 

1

S

AAA Batteries

2

T

Remote

1

PACKAGE CONTENTS 

(NOT shown actual size)

L

N

Q

O

P

M

R

S

T

Lowes.com

Lowes.com

SAFETY INFORMATION

Please read and understand this entire manual before attempting to assemble, operate or install the 
product.

Portable air conditioners exhaust large amounts of room air.  Always ensure an adequate supply of 
make-up air to operate effi ciently.

• Check available power supply and resolve any wiring problems BEFORE installation and 
operation of this unit. All wiring must comply with local and national electrical codes and be 
installed by a qualifi ed electrician. If you have any questions regarding the following instructions, 
contact a qualifi ed electrician.
• This appliance draws 9.5 nameplate amps and may be used in any properly wired general 
purpose 15 amp household grounded receptacle.

 

For your safety and protection, this unit is grounded through the power cord plug when plugged 

into a matching wall outlet. If you are not sure whether the wall outlets in your home are properly 
grounded, consult a qualifi ed electrician.

         DANGER

• Do not leave this unit unattended in a space where people or animals that cannot react to  

   

   a failed unit are located. A failed unit can cause extreme overheating or death in such an 
   enclosed, unattended space.

POWER SUPPLY CORD

The power cord supplied with this air conditioner contains a device that senses damage to the power 
cord. To test if your power cord is working properly, you must do the following:
• Connect the power supply cord to an electrical outlet.
• The power supply cord has two buttons located on the head of the plug. One button is marked  
  “TEST” and the other is marked “RESET.” Press the “TEST” button; you will hear a click as the  
  “RESET” button pops out.
• Press the “RESET” button; you will hear a click as the button engages.
• The power supply cord is now energized and supplying electricity to the air conditioner (on   
   some products this is also indicated by a light on the plug head.)

 Note:

 The power cord supplied with this air conditioner contains a current leakage detection 

   device designed to reduce the risk of fi re. In the event the power supply cord is damaged, it 
   cannot be repaired and must be replaced with a new cord from the product manufacturer.
• Under no circumstance should this device be used to turn the unit on or off. 
• The reset button must always be pushed in (engaged) for correct operation.
• The power supply cord must be replaced if it fails to reset when the “TEST” button is pushed in. 

PREPARATION

Before beginning assembly of product, make sure all parts are present. Compare parts with package 
contents list. If any part is missing or damaged, do not attempt to assemble the product.

Estimated Assembly Time:

 20 minutes

Tools Required for Assembly (not included): Phillips Screwdriver

         WARNING

• Improper connection of the grounding plug can result in risk of fi re, electric shock, and/or injury   
   to persons associated with the appliance. Check with a qualifi ed service representative if in 
   doubt that the appliance is properly grounded.
• DO NOT USE PLUG ADAPTERS OR EXTENSION CORDS WITH THIS UNIT. If it is 
   necessary to use an extension cord with this unit, use an approved “air conditioner” extension 
   cord only.
• To avoid the possibility of personal injury, always disconnect the power supply to the unit 
   before installing and/or servicing.

Содержание 416709

Страница 1: ...e Date Idylis is a registered trademark of LF LLC All Rights Reserved Questions problems missing parts Before returning to your retailer call our customer service department at 1 800 643 0067 Monday Thursday 8 a m 6 p m EST Friday 8 a m 5 p m EST ATTACH YOUR RECEIPT HERE AB12325 Lowes com ...

Страница 2: ...LE OF CONTENTS Package Contents 3 Safety Information 5 Preparation 5 AssemblyInstructions 6 Operating Instructions 8 Care and Maintenance 16 Troubleshooting 17 Warranty 18 Replacement Parts List 19 Lowes com ...

Страница 3: ...TY A Air Outlet 1 B Control Panel 1 C Castor 4 D Handle Hole 1 E Water Outlet Drain 1 F Air Outlet 1 G Power Supply Cord 1 H Water Outlet Drain 1 I Air Intake Condensor 1 J Air Intake Evaporator 1 K Air Filter 1 F A D C B E G H I J K Lowes com ...

Страница 4: ...lexible Exhaust Hose 1 M Exhaust Nozzle Connector 2 N Tube Adapter 1 O Screw 4 P Window Panel Extension 1 Q Window Panel 1 R Drain hose 1 S AAA Batteries 2 T Remote 1 PACKAGE CONTENTS NOT shown actual size L N Q O P M R S T Lowes com ...

Страница 5: ...on is marked TEST and the other is marked RESET Press the TEST button you will hear a click as the RESET button pops out Press the RESET button you will hear a click as the button engages The power supply cord is now energized and supplying electricity to the air conditioner on some products this is also indicated by a light on the plug head Note The power cord supplied with this air conditioner c...

Страница 6: ...d secure the tube adapter M from the front of the window panel P 3 Insert window panel extension O into the window panel P Lightly tighten the pre assembled screws in the window panel P to hold the extension O in place 6 ASSEMBLY INSTRUCTIONS Hardware Used M 1 2 Screws included 3 M P M P N O P x4 Lowes com ...

Страница 7: ...zzle connector L to each side of the exhaust hose K Then install one end of the exhaust hose K to the air oulet F on the rear side of the unit and the other end of the exhaust hose into the opening in the window panel P The minimum length of the exhaust hose is 21 13 20 in and the maximum length is 66 3 20 in when fully extended 4 Window Electrical outlet 5 Screws come attached Vertical Window Scr...

Страница 8: ...me time for more than 3 seconds the display will toggle between Celsius and Fahrenheit High Fan Speed Medium Fan Speed Low Fan Speed Warning Light the machine will stop running Keypad Functions Warning light Condensed water may accumulate in the unit If the internal tank becomes full the warning signal in the LCD display will light up and the unit will not operate until it has been drained LCD Dis...

Страница 9: ...d fan speed setting High Med Low Your selection will appear on the control panel each depression of the fan key will advance to a different setting Cooling stops automatically when the set temperature is achieved Cooling resumes when the room temperature rises above the set temperature level DRAINING EXCESS WATER If the water tank in the unit becomes full a full tank indicator light will come on T...

Страница 10: ... water tank this unit can be configured for continuous drain You can use the supplied drain hose Q to connect the continuous drain connector 2 Unscrew and remove the drain cover from the drain port at the rear of the unit 3 Remove the soft rubber stopper from the drain cover and place it in the water tank for safe keeping 4 Insert the drain hose Q through the hole of the drain cover 5 Ensure the r...

Страница 11: ...g Fan Mode the exhaust hose does not have to be vented outdoors 1 Press the POWER SWITCH button to turn the unit on 2 Press the MODE button until the FAN indicator illuminates on the control panel Each press of the MODE button will advance to a different mode setting Cool Dehumidifier Fan 3 Press the FAN button to select the desired FAN SPEED setting Your selection will appear on the control panel...

Страница 12: ... appropriate mode under which you want the unit to operate Cool Dehumidify Fan 4 Select the fan speed setting 5 The time you selected will appear in the LED display While the Air Conditioner is on Auto Off 1 Press the Timer button and the adjacent Auto Timer display will illuminate 2 Use the Up Down arrows to select a delayed Off Time of up to 24 hours 3 Follow the steps 3 4 and 5 the same as abov...

Страница 13: ...o operate the hand held remote control Batteries should be replaced when a No signal beep is heard when attempting to program the main unit using the remote b The main unit does not respond to a command issued by the remote control Battery replacement 1 Gently slide the rear cover on the remote in the direction of the arrow until it separates completely from the unit 2 Insert two Alkaline AAA batt...

Страница 14: ...03 11 The remote operates within a range of 26 ft from the receiver located inside the main unit Any obstruction between the receiver and remote may cause signal interference limiting the ability to program the main unit Note This equipment has been tested and found to comply with the limits for Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reason...

Страница 15: ...it 1 To remove the air filter Pull the air filter cover upward in the direction of the arrow and remove the air filter 2 Dust dirt clogged in the filter can be removed by vacuum cleaning the soiled areas 3 The filter can also be washed in lukewarm soapy water while rubbing it lightly with a brush A mild detergent such as dishwashing liquid is recommended 4 Rinse the filter well using clean water A...

Страница 16: ...ve drain water from drain tank refer to page 9 Unit runs intermittently 1 Malfunction 2 Surrounding temp is more warm more cool than current heat cool setting 3 Exhaust duct hose is blocked 1 Contact your dealer 2 This is normal Unit doesn t need to be operating constantly in this condition 3 Check and unblock the duct hose Unit functions but the room is not cooled 1 Window or door is open in room...

Страница 17: ...s to and from the service location are not protected by this warranty and are the responsibility of the purchaser Nothing within this warranty shall imply that manufacturer will be responsible or liable for any spoilage or damage to food or other contents of this appliance whether due to any defect of the appliance or its use whether proper or improper EXCLUSIONS Save as herein provided manufactur...

Страница 18: ...50 13 DISCHARGE PIPE A6209 550 14 CONDENSER ASS Y A3422 550 15 Y TUBE D6210 060 16 CAPILARY TUBE A6204 520 17 FAN CASING A5301 340 AB 22 18 FAN MOTOR LS 53T1 4P A3020 070 19 BLOWER WHEEL A5304 450 AH 11 20 FAN CASING A5301 320 A 22 21 DISCHARGE GRILLE A4239 370 H 22 22 CAPACITOR 9uF 250V FOR No 19 A2509 410 23 CAPACITOR 4uF 250V FOR No 33 A2509 060 24 TERMINAL BLOCK A2525 020 25 COVER A6101 800 AF...

Страница 19: ...IR DEFLECTOR A4244 430 50 VAN AIR DEFLECTOR A4244 440 51 FIXTURE A5825 310 52 FIXTURE A5825 320 53 COVER A6105 200 54 SIDE PLATE A4211 680 55 SIDE PLATE A4211 690 56 TOP COVER A4206 630 57 HEAT EXHAUST HOSE CONNECTOR A5815 320 58 POWER SUPPLY CORD COMPLETE A3701 800 59 PLUG D7306 150 60 SOFT CAP D7324 030 61 WASHER D3204 060 62 INTAKE GRILLE A4262 300 63 HEAT EXHAUST HOSE A6200 270 64 SCREEN A7204...

Страница 20: ...1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 58 59 60 62 64 72 Lowes com ...

Страница 21: ...Printed in China Idylis is a registered trademark of LF LLC All rights reserved 57 61 63 65 66 67 68 69 70 71 ACCESSORIES 57 61 63 65 66 67 68 69 70 71 ACCESSORIES Lowes com ...