ID GATE 6000 Electromechanical Tripod Turnstile
9
Figure 4. Control Logic Board (CLB)
The CLB (Fig. 4) includes:
•
X1
(
LED
),
X2
(
SENS
),
X3
(
MOTOR
) connectors to connect the indication module,
optical arm rotation sensors and control mechanism with a locking device (from the
X1, X2, X3 connectors with the turnstile cable);
•
XT1.L
(
In
) connector block to connect the RC panel / WRC / ACS controller inputs
as well as an emergency unblocking device (
Fire Alarm)
and intrusion detector;
•
XT1.H
(
Out
) connector block to connect a siren and ACS outputs, providing the
turnstile status data to the ACS controller;
•
XT3
(
+12VDC
) connector block to connect the turnstile power supply;
•
XT4
(
Light A
) and
XT5
(
Light B
) connector blocks to connect
“open/closed”
remote
indicators, one indicator per each direction;
•
XT6
(
AntiPanic
) connector block to connect the electromagnet of automatic
anti-panic unblocking device;
•
J1
connector to select the turnstile control mode, the jumper is fixed
—
the pulse
control mode, the jumper is not fixed
—
the potential control mode. The jumper is
fixed at the factory before the delivery
•
J2
connector for programming.
•
Power
–
power LED indicator on the control board.
5.3 Control devices of the turnstile
The turnstile can be operated from the following control devices:
•
the RC panel;
•
the WRC;
•
the ACS controller.
The above devices can be connected to the turnstile as follows:
•
any device separately;
•
in any combination with each other;
•