ID GATE 8900
10
4.1
Gate Position Adjustment
1.
Press
“Set”
(middle button) for 5 times continuously, the system will prompt "please adjust gate manually".
2.
Push the gate to the target position and stop it for 3 seconds. The speaker prompt "beep" or the LED light flashes once, the
system will take the current position as the target position.
* The system will automatically determine whether the target position is left, right or middle target position.
3.
Finally, push the gate to the middle target position
and holding for about 10 seconds. The system will prompt “adjustment completed
“, then the whole program is finished.
*In most cases, the system will automatically obtain the appropriate left position and right position, and the user only needs to adjust
the middle position.
4.2
Parameter Setting
1.
Long press the
“Set”
button, till the nixie tube flashes.
2.
The
"Menu"
button for choosing the menu, the
"Value"
button for setting the parameter.
3.
Long press the
"Set"
button 2S, the digital tube stops flashing, then menu values are saved successfully.
Figure 5
Menu
Function
Range
Default
Parameter function description
0
Machine num
ber
1~99
1
For 485 communication
1
Unlock mode
1~4
1
1: standard
2: IR1 trigger
3: IR4 trigger 4: IR1 trigger and IR4 trigger
2
Keeping unlock tim
e
1~20
6
Time unit: Second
3
Voice for O
pen-L
0~9
0
0, thank you; 1, come in; 2, good bye;
3, welcome; 4,see you;
5,have a nice day;
6, have nice trip;
7, please put on your safety helmet; 8, Verify success; 9
null(mute);
4
Voice for O
pen-R
0~9
3
5
Volume
1~9
5
The higher the value, the higher the volume
6
Main motor speed
1~25
13
The higher the value, the higher the speed
7
Slave motor speed
1~25
13
8
Restore factory
0~2
0
1: Automatic aging test
2: Restore factory
4. Equipment Function Debugging