Quick Install Guide
5
4. Normal Operation
4.1 Power ON
When the power is applied to iCON100, the Red LED (LED1) is turned on.
4.2 Registered card reading
When a registered card (or PIN) is read, the Door (Relay 1) will be opened for 3 seconds (Default) with the Green LED (LED2)
light on.
4.3 Exit Button
The Exit Button or the Exit Reader should be installed inside.
When the Exit Button is pressed, the door will be opened for 3 seconds with the Green LED (LED2) light on.
4.4 Alarm (Unregistered ID/PW Error/TS Error/Door Error)
When an unregistered card is read, or any wrong password is input, or any error over the time schedule and the door access is
occurred, the access is denied and the alarm will be activated for 3 seconds (Default) with the Yellow LED (LED 3) light on.
LED1: Power ON/OFF Status
LED2: Door Relay Status
LED3: Alarm Relay Status
1
2