13
10-7. SR10RW Configuration
The SR10RW is connected to PRG2000RW for access control, debt meal and cashless payment.
To know connection methods, refer to the user‟s manual of PRG2000RW or Smart Card Read / Write
Software.
The SR10RW supports RS232 or RS485 communication on the all field. Their communication is set
by DIP switch. The SR10RW also supports 26/34bit Wiegand output format when it is set for access
control.
10-8. 8 Channel DIP Switch Setting
There is an 8 channel DIP switch and the switch is used to set Board ID, RS232/RS485, Temper
output and Initialization.
Switch Number.
Description
No. 1 - 5
Board ID Setting (See the „Board ID Example‟ below)
No. 6
RS232 or RS485 (0: RS232, 1: RS485)
No. 7
Tamper output enable / disable (0: Enable, 1: Disable)
No. 8
Initialization (For initialization, switch on to „1‟ position and keep it about 1.5
seconds and then switch down to „0‟ position.)
※
Board ID Example
The 5 switches (No.1 ~ 5) are used to set board ID. Each switch has assigned address value and
the Board ID is the sum value of each switch set to “1” position. Board ID can be set from „0‟ to „31‟.
Refer to the example below.
(Figure: Address Value)
RW