10
December. 2016 Copyright IDTECK Co., Ltd
.
User Manual
7. Cable Color
Cable name
Color
Main Power(DC+12V)
Red
Power Ground(GND)
Black
Wiegand Data-0
Green
Wiegand Data-1
White
BARGATE
1)
Gray
HOLD Loop INPUT
2)
Blue
OTR INPUT
3)
Yellow
RS232_TX
Purple
RS232_RX
Brown
BOOT_INPUT
4)
Orange
1.
BARGATE output (a transistor output) that directly controls a car circuit breaker is used for circuit
breaker control relay operation. The maximum current drain rate is 1 Amps.
2.
HOLD input is used to force NEO RF245 to read a tag when loop sensor detects any approaching
vehicle. When a vehicle is detected, NC contact should be used, and the input should also be
disconnected from GND completely. In OTR mode, the reader will only output tag ID (1 time).
CAUTION: Nothing should be connected to this input unless loop sensor is in use.
3.
OTR cable (yellow) is used to limit the reading time to 1 (OTR = One time reading).
4.
When BOOT_INPUT is connected to GND during firmware upgrade, the system changes into
applicable mode.