0x550F
Other Error
0x6000
Save or Config Failed / Or Read Config Error
0x6200
No Serial Number
0x6900
Invalid Command - Protocol is right, but task ID is invalid
0x6A00
Unsupported Command - Protocol and task ID are right, but command is
invalid
0x6B00
Unknown parameter in command - Protocol task ID and command are right,
but parameter is invalid
0x7200
Device is suspend (MKSK suspend or press password suspend)
0x7300
PIN DUKPT is STOP (21 bit 1)
0x7400
Device is Busy
0x8100
Timeout for "Get Fun key" & "Get Encrypted PIN" & "Get Numeric"
NOTES
If Security Chip is not connect, Response Body is 15 30 FF
If Security Chip is de-activation for No Secure data (Unit is In Removal Legally State),
Response Body is 15 30 00
If Security Chip is de-activation for ST Chip Firmware Check Error (Unit is In Removal Legally
State), Response Body is 15 30 01
If Security Chip is de-activation for Security Chip Firmware Check Error (Unit is In Removal
Legally State), Response Body is 15 30 02
If Security Chip is de-activation for Illegally Removal, Response Body is 15 30 03
If Security Chip is activation (Unit is In Removal Legally State), Response Body is 15 31 01
If Public Key is not loaded, while receiving below Commands, Response Body is 15 04 00
Load Firmware Key
Load Numeric Key
Load ST Chip Check Value
Load MAXQ Chip Check Value
If Public Key is loaded, while receiving Load Public Key Command, Response Body is 15 0D
00
If Firmware Key is not loaded, while receiving below Command, Response Body is 15 04 01
Load ST Chip Check Value
Load MAXQ Chip Check Value
If Firmware Key is loaded, while receiving Load Firmware Key Command, Response Body is
15 0D 00
If Firmware Check Value is loaded, while receiving Load Firmware Check Value Command,
Response Body is 15 0D 00