Copyright © 2010-2014, International Technologies & Systems Corp. All rights reserved.
Page 19 of 74
SecureMag User Manual
Other possible response statuses:
18
'Q' command length must be 1
18
Reader not configured for buffered mode
NAK Already armed
NAK for keyboard interface is FD, non-KB mode NAK is 15
7.7
Read MSR Options Command
02 52 1F 03 LRC
<Response> format:
The current setting data block is a collection of many function-setting blocks
<FuncSETBLOCK> as follows:
<STX><FuncSETBLOCK1>…<FuncSETBLOCKn><ETX><CheckSum>
Each function-setting block <FuncSETBLOCK> has the following format:
<FuncID><Len><FuncData>
Where:
<FuncID> is one byte identifying the setting(s) for the function.
<Len> is a one byte length count for the following function-setting block <FuncData>
<FuncData> is the current setting for this function. It has the same format as in the
sending command for this function.
<FuncSETBLOCK> are in the order of their Function ID<FuncID>
7.8
Set MSR Options Command
The default value is listed
in bold
.
7.8.1.
Beep Volume
The beep volume and frequency can be each adjusted to two different levels, or
turned off.
02 53 11 01 <Beep Settings>03 LRC
Beep Settings:
‘0’ for beep volume off
‘1’ for beep volume high, low frequency
‘2’ for beep volume high, high frequency
‘3’ for beep volume low, high frequency
‘4’ for beep volume low, low frequency
7.8.2.
Change to Default Settings
02 53 18 03 LRC