  Test the ViVOpayKiosk III installation using a test card to perform an end-to-end transaction 

(the same as an actual purchase on the Kiosk). The kiosk control panel should display 
"Requesting Authorization". Even if the transaction is declined (as it should be with a test card), 
it will prove connectivity all the way through the system. If possible the store manager or some 
other responsible party should test each ViVOpayKiosk III on a regular basis (perhaps at the 
start of each day or at least once per week) with a test card to ensure continued operation and 
functionality. If the kiosk is rebooted on a regular basis (such as every night) it is important to 
test the contactless reader as soon as possible afterwards to ensure continued communication 
to the kiosk. 

  Refer to the troubleshooting section of this manual before contacting your distributor with 

support questions. 

4 RF 

Interference 

 

Q. Why do I need to know about RF interference?  

A.

 Contactless payment uses radio frequency technology to send card data to a contactless 

terminal reader. 

Q. How can RF interference affect contactless payment?

 

A.

 RF interference can cause data errors. If RF interference is present, contactless payment 

devices may operate intermittently or inconsistently. 

Q. Where does RF interference come from?

 

A.

 Radio frequency interference (RFI) can originate from a wide number of sources at the 

point-of-sale (POS). Some examples of sources of RF energy and RF interference include: 

AM/FM radio and TV transmitters 
2-way radios, pagers 
Mobile telephones 
Power lines, transformers 
Medical equipment 
Microwaves 
Electromechanical switches 

Q. What should I do if I suspect RF interference exists in my environment?

 

A.

 Begin by inspecting your environment for possible sources of RF interference. 

Q. Do equipment manufacturers test their devices for RF interference?

 

A.

 Electronic equipment is tested for RFI sensitivity by the manufacturers. These tests are 

performed in a controlled laboratory environment and will often not replicate the types of 
devices that would be encountered in your point-of-sale (POS) environment. 

Q. What RF levels will impact RF operations?

 

A.

 Factors that can cause RF interference vary case-by-case. There are no set rules defining 

a single RF level that will cause RFI. RFI depends on the sensitivity of the equipment under 
consideration, or how low an interpreting signal can be in the presence of the equipment and 
cause problems. 

Equipment can be particularly sensitive to very low signal levels of one frequency and yet be 
quite immune to high signal levels of another frequency - so frequency is an important factor. 

Some electronic system components are internally shielded and have a very high immunity to 
interference; but generally, most equipment has not been so engineered. 

 

Содержание Kiosk III

Страница 1: ...User Manual Kiosk III 80136500 001 Copyright...

Страница 2: ...recorded or any other method or translated into another language or language form without the express written consent of ID TECH ID TECH is a registered trademark of International Technologies and Sy...

Страница 3: ...adio TV technician for help Changes or modifications to the ViVOpay Kiosk III not expressly approved by ViVOtech could void the user s authority to operate the ViVOpay Kiosk III IC Compliance Warning...

Страница 4: ...osk III Controller 11 2 3 1 Mounting the ViVOpay Kiosk III Controller Using Screws 11 2 3 2 Mounting the ViVOpay Kiosk III Controller Using Mounting Tape 12 2 4 Connecting to Power 12 2 5 Connecting t...

Страница 5: ...can besupplied via a single cable toreducing the effort and complexity of installation 1 1 Features Supports ISO 14443 Type A Type B and optional Type C Felica Supports ISO 18092 with protocol stacks...

Страница 6: ...O 18092 Typical Read Range 4 6 cm 1 5 to 2 3 inches Physical Controller Height 105 mm 4 13 inches Width 76 2 mm 3 00 inches Depth 22 5 mm 0 88 inches Square Bezel Antenna Height 75 mm 2 95 inches Widt...

Страница 7: ...Temperature 10 C to 50 C 14 F to 122 F duration 3 months Transit 40 C to 60 C 40 F to 160 F duration 1 week Operating Humidity 5 to 90 non condensing Storage Humidity 10 to 90 non condensing duration...

Страница 8: ...fy that you have the following hardware for the installation of the ViVOpayKiosk III ViVOpay Kiosk III Controller ViVOpay Kiosk III Antenna either square or angle bezel Antenna LED power and data cabl...

Страница 9: ...locate and mark the four 4 4mm 0 173 inch mounting holes 2 Using the Drill Template locate and mark the two 14 0 mm 0 551 inches access holes used for connecting the antenna power and the LED power a...

Страница 10: ...kiosk Make sure to tighten the nuts securely so that the ViVOpay Kiosk III does not move on the outside surface of the kiosk If you are installing the Angle Bezel Antenna tighten the nuts to 5 7 in l...

Страница 11: ...llation 2 3 Mounting the ViVOpay Kiosk III Controller Note The ViVOpay Kiosk III Controller must be mounted within 1 meter of the antenna If the antenna is mounted of a surface that opens such as a do...

Страница 12: ...VOpay Kiosk III Controller Using Mounting Tape 1 Position the ViVOpay Kiosk III Controller on the interior of the kiosk making sure that there is sufficient room for the antenna mounting surface to be...

Страница 13: ...er ground 4 7 5v to 45VDC 5 No connection 6 Reserved 7 Reserved 8 Reserved 9 Signal ground 10 Signal ground 11 RS 232 Tx 12 RS 232 Rx 13 No connection 14 Reserved To build your own RS 232 cable use Mo...

Страница 14: ...has been entered on the kiosk control panel the customer should present their card fob phone in close proximity so that maximum surface area is parallel to the antenna A single beep and all four LEDs...

Страница 15: ...erference come from A Radio frequency interference RFI can originate from a wide number of sources at the point of sale POS Some examples of sources of RF energy and RF interference include AM FM radi...

Страница 16: ...t polarity is observed For more information refer to the Input Voltage under the Electrical specification section Replace the ViVOpay Kiosk III Reading Cards Fobs Phones LEDs do not light and beeper i...

Страница 17: ...e The Kiosk III can be upgraded using either the serial or USB interfaces 6 1 Preparation To update the new firmware you will need PC with available serial or USB port Kiosk III with a serial data cab...

Страница 18: ...of 18 6 Press the button Load to load the firmware on the reader the progress will be displayed 7 Disconnect power and the serial dongle if connected 8 Connect power to the Kiosk III and connect the s...

Отзывы: