![IDTECH BluScan Скачать руководство пользователя страница 125](http://html.mh-extra.com/html/idtech/bluscan/bluscan_user-manual_618721125.webp)
122
String setting / Transmission
(Insert Group Characters)
Insert G1/G2/G3/G4 character setting:
The imager
supports inserting two groups with each group 22 characters
into transmitted data of selected symbologies. The two
groups can be inserted into scanned data of the selected
symbologies or positioned at leading / ending of data. There
are total four groups for utilization.
Insert data group position:
To define the position of a group
to insert into bar code data. Please notice that the inserting
position of a group must not exceed the code length; or the
insertion will be positioned at the ending of data.
Notice:
Default value “00” indicates the group to be
positioned at the leading of data. “64” represents for
positioning the group at the ending of data.
Insert data group setting procedure:
i.
Define the characters of groups for insertion.
ii.
Setup the inserting position of each group in
scanned data.
iii.
Select one or two groups to insert into specific
bar codes. Please refer to the setting pages of
each bar code.
Example: Barcode “1 2 3 4 5 6”.
Output- Barcode “1 2 A B 3 4 C D 5 6”.
Steps:
1) Scan Programming and
Insert G1 characters setting
barcode.
2) Use the ASCII code table to find the value of A
→
41,B
→
42.
3) Scan 4, 1 and 4, 2 from the barcode on the fold out back
page.
4) Scan Finish from the barcode on the fold out page.
Содержание BluScan
Страница 1: ...BluScanTM Barcode Scanner User s Manual 80106502 001 rev A ...
Страница 9: ...6 8 Select COM23 depending on your Outgoing COM port to connect ...
Страница 29: ...26 z Level 6 z Level 7 5AK06 5AK07 ...
Страница 61: ...58 Exit Truncate ending 0 15 00 15 00 Code ID setting 00 ffH ASCII code 00 ffH E ...
Страница 65: ...62 Exit Truncate ending 0 15 00 15 00 ...
Страница 71: ...68 Exit Expansion Disable Enable 00 01 ...
Страница 93: ...90 Exit Code ID setting 00 ffH ASCII code 00 ffH Insert group number selection 00 44 00 44 00 ...
Страница 109: ...106 Exit Insert group number selection 00 44 00 ffH 00 44 00 ...
Страница 113: ...110 Exit UCC EAN128 emulation Disable Enable 00 01 ...
Страница 121: ...118 Exit Insert group number selection 00 44 00 44 00 Escape sequence transmit None GLI protocol ECI protocol 00 01 02 ...
Страница 132: ...129 PDF 417 STANDARD 25 PARA CODE 16K EAN 8 PARA INDUSTRIAL 25 PARA UPCE PARA 87549 ...
Страница 133: ...130 INTERLEAVED 25 PARA MATRIX 25 PARA MSI PLESSEY PARA UPCA PARA UK PLESSEY PARA GS1 DataBar Omnidirectional Micro PDF ...
Страница 137: ...134 0 1 2 3 4 5 6 7 8 9 A B C Finish F E D ...