background image

 

6 of 13 

Press and release the 

SCAN

 button to activate the All Scan function. The SCAN and ALL indicator appears 

on the LCD during All Scan. In All Scan mode, all channels in the channel set are scanned in sequence 

except the channel set as Cancel channel using SKIP button operation. After the last channel number has 

been scanned, the cycle repeats.   

 

3CH Scan ( Favourite Channels Scan) 

Press 3CH button into 3CH shortcuts button when there is at least one favourite channel 

Press and release the 

SCAN

 button to start 3CH Scan , the SCAN indicators appear on the LCD. Only the 

favourite channels and priority channels (CH16) are scanned in sequence.   

Your radio can store up to three favourite channels. The favourite channels are the ones scanned in 

the 3CH Scan mode. Press 3CH shortly can access these favourite channels as shortcuts 

To Add Channels to 3CH List   

During normal operation mode, use the UP or DOWN key to select the desired channel for 

programming.   

Press and hold the 

3CH

    button for 3 seconds. The "C1" icon appears to indicate the current channel 

has been saved in first favourite channel. The similar to the second and third favourite as C2 and C3 

respectively. Any number of channels can be saved as favourite channels 

To Delete Channels from 3CH List 

Press 3CH shortly into 3CH shortcuts mode, press 3CH repeatedly until the channel to be deleted. 

Press and Hold 3CH button more than 3 seconds until the “Cn” disappears 

 

 

Monitor Modes (Dual Watch) 

The Watch Modes monitor the programmed Priority Channel (CH16) and other user selected channel. The 

watch is halted when activity is detected on a monitored channel. 

Press SCAN shortly to activate the Dual Watch mode. The "DW" indicator appears on the LCD. Dual Watch 

monitors the current working channel and Channel 16 in cycle. Press SCAN button to terminate Dual Watch 

and return to the previous working channel. 

Note: During Dual Watch mode, the SCAN and Channel 

(UP/DOWN) button are inactive and 

sounds an error beep if pressed. 

 

Monitor modes are terminated when the PTT once pressed.

 

 

NOAA WEATHER CHANNELS 

To receive a NOAA weather channel, press the [WX] key from any channel. The transceiver will go to the 

last selected weather channel. 

Press the 

(UP/DOWN )

button to scroll through the available channels.   

To exit from the NOAA weather channels, press the [WX] key. The transceiver returns to the channel it was 

on prior to a weather channel. Or press 16/9 to access the priority channels 

 

NOAA WEATHER ALERT 

In the event of extreme weather disturbances, such as storms and hurricanes, the NOAA (National Oceanic 

and Atmospheric Administration) sends a weather alert accompanied by a 1050 Hz tone and subsequent 

weather report on one of the NOAA weather channels.   

When the Weather Alert feature is enabled, the transceiver is capable of receiving this alert   

In the Weather channel, Press and hold Wx button more than 3 seconds to active the Alert function, LCD will 

appears “ALT”. To cancel the alert function, Press and hold WX button more than 3 seconds again, the “ALT” 

Содержание EVR-100

Страница 1: ...1 of 13 EVR 100 VHF Marine Radio Owner s Manual...

Страница 2: ...arine VHF channel bands USA Canada International including Weather channels where available Special CH16 or CH16 9 key for quick access to the priority international distress channel Special 3CH key t...

Страница 3: ...ndom noise is heard then turn slowly clockwise until the random noise disappears Make another 1 4 turn clockwise for best reception in open sea conditions In areas of high noise e g close to large cit...

Страница 4: ...to enter ALL SCAN mode where the priority channel is checked every 1 5 seconds When a signal is received scanning stops at that channel and BUSY appears on the screen If the signal ceases for more th...

Страница 5: ...CD and Hi appears on LCD when operating at high power Some channels allow only low power transmissions Error beeps will sound if the power transmission setting is incorrect Some channels allow only lo...

Страница 6: ...until the Cn disappears Monitor Modes Dual Watch The Watch Modes monitor the programmed Priority Channel CH16 and other user selected channel The watch is halted when activity is detected on a monito...

Страница 7: ...Explain the nature of your distress sinking collision aground fire heart attack life threatening injury etc 5 State the kind of assistance your desire pumps medical aid etc 6 Report the number of pers...

Страница 8: ...it and dust cover Yes Local Distant control No Position polling No Group Call No Channel Naming No Dual watch Favourite channel scan All scan Yes TRANSMITTER Frequency 156 025 157 425MHz Output power...

Страница 9: ...er makes popping or whining noises when the engine is running Electrical noise may be interfering with the transceiver a Re route the power cables away from the engine b Add a noise suppressor to the...

Страница 10: ...70 156 525 156 525 S DSC 12 156 600 156 600 S 71 156 575 156 575 S 13 156 650 156 650 S 72 156 625 156 625 S 14 156 700 156 700 S 73 156 675 156 675 S 15 156 750 156 750 S 1W Only 74 156 725 156 725 S...

Страница 11: ...3 156 650 156 650 S 1W Only Override 72 156 625 156 625 S 14 156 700 156 700 S 73 156 675 156 675 S 15 156 750 Rx Only 74 156 725 156 725 S 16 156 800 156 800 S 77 156 875 156 875 S 1W Only 17 156 850...

Страница 12: ...650 S 1W Only Override 71 156 575 156 575 S 14 156 700 156 700 S 72 156 625 156 625 S 15 156 750 156 750 S 1W Only 73 156 675 156 675 S 16 156 800 156 800 S 74 156 725 156 725 S 17 156 850 156 850 S...

Страница 13: ...3 WX WX FREQUENCY MHz FREQUENCY MHz CH TX RX MODE REMARK CH TX RX MODE REMARK WX01 162 550 WX06 162 500 WX02 162 400 WX07 162 525 WX03 162 475 WX08 161 650 WX04 162 425 WX09 161 775 WX05 162 450 WX10...

Отзывы: