Trouble conditions
If a trouble condition is detected, the power LED will begin to flash. Displaying of trouble conditions are
programmable via the installer programming location 16.
To see what trouble condition has been encountered press and hold the [7] key.
The zone LEDs will indicate the trouble condition on a LED keypad, shown in the table below.
Zone
LED
Trouble Condition
Description
1
Panel AC Supply Failure
When there is no more supply voltage and the system is running on battery
2
Panel
Communications
Failure
When the system has tried to send an event via telephone, but could not
reach the control room
3
Telephone Line Trouble
If the telephone line voltage is no longer detected
4
Siren Tamper
If the siren wires are cut
5
Low Battery
The system checks the battery constantly and if lower than 11V a trouble is
triggered
6
Aux 12V Resettable Fuse
Blown
If the auxiliary 12V supply is no longer supplying voltage this trouble condition
will display
7
Engineer reset
When this option is set, and an alarm condition is triggered, the alarm can
only be armed again, once the installer code has been entered
8
Box tamper
The panel has pins to connect a switch that can monitor if the box is opened
9
Peripheral Device Tamper
Any device that is tampered with that is connected to the communication bus
10
Peripheral Communications
Failure
If a device stops communicating on the communication bus
11
Peripheral Low Supply
Voltage
If a device on the communication bus detects that its voltage is less than 11V
12
Wireless battery low
When a wireless device’s battery needs to be replaced the device will send
a battery low signal and trigger a trouble if enabled
13
Wireless supervision
Monitoring
Each wireless device will check in and if a device does not a trouble is
triggered
14
Wireless RF jam
If an unknown signal that can interfere with signals from wireless is detected
a trouble will be triggered
15
Wireless low RSSI
RSSI is signal strength measurement and if lower than 20% a trouble will be
logged
16
Zone tamper
If a zone is monitored for tamper and then a tamper signal is detected by the
alarm a trouble will be triggered.
Once the trouble has been corrected, press and hold [7] again, and [#] immediately thereafter. AC failure
will clear automatically, once AC has been restored.