background image

X-SMS 700-485-01B 

 
   

 

 

X-SMS Quick User Guide 

THANK YOU FOR CHOOSING IDS TO PROTECT YOU 

Thank you for purchasing an IDS X-SMS module. IDS X-SMS offers 
powerful, versatile and highly configurable reporting and control 
capabilities, which will keep you, informed and in control of your X-Series 
alarm system when away from your premises.  

NOTE:

 The X-SMS module works only with IDS X-Series panels above a 

certain version. Your X-Series alarm panel is a sophisticated professional-
grade intrusion product designed to protect lives and property, and can 
only be installed and maintained by a professional IDS-certified installer. 
The Installer Manual included in this box does not cover all aspects of 
installation; these are available only to installers via our sales offices. 
Should you require assistance in finding an installer, please visit 

www.idsprotect.com

.   

NOTE: 

Please read the entire Quick User Guide before attempting to use 

the X-SMS device!

 

NOTE: 

Throughout this manual, the default user code 1234 is used. 

Commands will only be accepted by the alarm panel if preceded by a 
valid user code, programmed into the alarm panel by your installer. 

FEATURES OF THE IDS X-SMS DEVICE 

 

Take full remote control of your X-Series alarm panel 

o

 

Arm / disarm 

o

 

Bypass / un-bypass zones 

o

 

Home automation via PGM’s 

 

Keep in touch with your premises 

o

 

Receive customised reports on panel status and events 

o

 

Check current panel status  

o

 

Check recent activity by retrieving event logs 

 

Enhance the functionality of your X-Series alarm panel: 

o

 

Using names in reporting and commands 

o

 

Update your panel’s time and date via the mobile network 

 

Manage your X-SMS device remotely 

o

 

Lock X-SMS in event of lost phone 

o

 

Check and top up SIM airtime balance  

o

 

Add, manage and remove X-SMS users  

COMMAND FORMAT 

Commands are not case sensitive and all follow the same format for ease 
of use: 

[code]

 

space

 

[command] 

space

 

[extended command] 

space

 

[data

Code

 – Valid alarm user code stored in the alarm panel 

Command

 – A string that identifies the function that you are wanting to 

access in the alarm panel. 

Extended Command

 – Any supplementary information the function 

requires. (Not always required will depend on the function you are 
accessing) 

Data

 - Any extra information the extended command requires.  

NOTE: 

The cell networks limit the number of characters to 160. 

TAKE FULL REMOTE CONTROL OF YOUR X-SERIES ALARM PANEL 

Arm / Disarm 

The X-Series panel’s 8 partitions may be armed in multiple profiles. 
Arming requires a valid user code. These are programmed by your 
installer.  
Valid command examples: 

Desired action 

Code  Command  Ext. Comm  Data 

Away arm all partitions 

1234 

Arm 

 

All 

Away arm P1 & P3 

1234 

Arm 

 

P1, P3 

Stay arm P2 in stay profile 3  1234 

Arm 

S3 

P2 

Stay arm P1 & P4 in stay 
profile 1 

1234 

Arm 

S1 

P1, P4 

Disarm all partitions 

1234 

Disarm 

 

All 

Disarm P2 

1234 

Disarm 

 

P2 

Disarm P5 & P6 

1234 

Arm 

 

P5, P6 

NOTE

: Stay profiles can be changed by sending a new stay arm command 

If a partition is away armed and a stay arm command is sent the 
message will be rejected. Away armed partitions must be disarmed 
before being stay armed. 

Bypass / un-bypass zones 

The “Bypass” command will be sent by you to bypass specific zones, and 

vice versa

 for “unbypass”. You must specify which zones to bypass in the 

data field. Zones may be referred to by their number or, where 
applicable, by their name.  
Valid command examples: 

Desired Action 

Code  Command  Ext. Comm  Data 

Bypass zone 1 

1234 

Bypass 

 

Bypass zone 3,4,8,10 

1234 

Bypass 

 

3,4,8,10 

Bypass named zone 
“Passage” 

1234 

Bypass 

 

Passage 

Bypass named zone “Lounge” 
& “Kitchen” 

1234 

Bypass 

 

Lounge, 
Kitchen 

Unbypass Zone 5 

1234 

Unbypass 

  

Unbypass “Kitchen” 

1234 

Unbypass 

  

Kitchen 

Home automation via PGM’s 

Programmable outputs (PGM’s) on your X-Series alarm panel may be 
used to control electrical devices such as lights, gate and garage doors 
motors, pumps, geysers, irrigation systems etc. The PGM command 
controls the programmable outputs on the X- Series alarm panel.  

Note: Installations controlling electrical devices often requires a certified 
electrician. PGM outputs can only supply 80mA of current. 

PGM’s can be triggered in several ways as below – consult your installer 
for further support.  

 

On – Turns the PGM on by putting 12V DC onto the output  

 

Off – Turns the PGM off by removing the 12V DC 

 

PulseH – Puts 12V DC onto the output for 2 seconds 

 

PulseL – Removes 12V DC from the output for 2 seconds 

 

 

Desired Action 

Code  Command  Ext. Comm  Data 

Turn PGM 1 on 

1234 

PGM 

 On 

Turn PGM 3, 4 & 5 off 

1234 

PGM 

Off 

3,4,5 

Pulse PGM 2 Low 

1234 

PGM 

PulseL 

Pulse PGM 3 High 

1234 

PGM 

PulseH 

KEEP IN TOUCH WITH YOUR PREMISES 

Receive customised reports on panel status and events 

The “report” command is sent to select what reports you want to receive 
on that phone number. Each phone number can choose how they want 
to receive the messages or turn off messages. 

There are three types of SMSes: 

Raw – A Contact ID string will be sent to the phone number 

Full – All enabled events on the X-Series alarm panel will be sent in 

English to the phone number 

Partial – Only the following will be sent in English to the phone number: 

Panics, Duress, zone violations AC Fail/Restore and Battery 
low/restore 

Valid extended commands: “Type” 

Desired Action 

Code 

Command  Ext. Comm  Data 

Turn on partial reporting  

1234 

Report 

Type 

Partial 

Turn on global reporting  

1234 

Report 

Type 

Full 

NOTE

: Only a “Master Phone Number” can allocate partitions to a phone 

number. 

Check current panel status 

Current arm status, zone status, and PGM status can be checked. 

Arm Status 

Desired Action 

Code 

Command  Ext. Comm  Data 

Retrieve the status of  all 
partitions 

1234 

Arm 

Status 

All 

Retrieve the status of  P1 

1234 

Arm 

Status 

P1 

Retrieve the status of  P3 & 
P6 

1234 

Arm 

Status 

P3, S6 

Zone Status 

Desired Action 

Code 

Command  Ext. Comm  Data 

Retrieve the status of zones 
in partition 1 

1234 

Zone 

Status 

P1 

Retrieve the status of zones 
in partition 1 & 3 

1234 

Zone 

Status 

P1, P3 

PGM Status 

Desired Action 

Code 

Command  Ext. Comm  Data 

Get PGM 8’s status 

1234 

PGM 

Status 

Get PGM Gate’s status 

1234 

PGM 

Status 

Gate 

 

 

 

 

Содержание X Series

Страница 1: ... by a valid user code programmed into the alarm panel by your installer FEATURES OF THE IDS X SMS DEVICE Take full remote control of your X Series alarm panel o Arm disarm o Bypass un bypass zones o Home automation via PGM s Keep in touch with your premises o Receive customised reports on panel status and events o Check current panel status o Check recent activity by retrieving event logs Enhance ...

Страница 2: ...ass in the data field Zones may be referred to by their number or where applicable by their name Valid command examples Desired Action Code Command Ext Comm Data Bypass zone 1 1234 Bypass 1 Bypass zone 3 4 8 10 1234 Bypass 3 4 8 10 Bypass named zone Passage 1234 Bypass Passage Bypass named zone Lounge Kitchen 1234 Bypass Lounge Kitchen Unbypass Zone 5 1234 Unbypass 5 Unbypass Kitchen 1234 Unbypass...

Страница 3: ...zone violations AC Fail Restore and Battery low restore Valid extended commands Type Desired Action Code Command Ext Comm Data Turn on partial reporting 1234 Report Type Partial Turn on global reporting 1234 Report Type Full NOTE Only a Master Phone Number can allocate partitions to a phone number Check current panel status Current arm status zone status and PGM status can be checked Arm Status De...

Страница 4: ...Comm Data Name PGM 5 Lights 1234 PGM Name 5 Lights Name the X SMS device Home 1234 Site Name Home Name partition 1 Main House 1234 Partition Name 1 Main House Name partition 2 as Granny Flat partition 3 as Garage 1234 Partition Name 2 Granny Flat 3 Garage Name zone 1 as Kitchen 1234 Zone Name 1 Kitchen Name zone 2 Lounge zone 5 Patio 1234 Zone Name 2 Lounge 5 Patio NOTES The X Series alarm system ...

Страница 5: ...airtime Desired Action Code Command Ext Comm Data Save balance string in the SMS module 1234 Airtime Command Enter the string supplied Query airtime balance 1234 Airtime Balance Add airtime 1234 Airtime Network supplied string Add manage and remove X SMS users Phone Number Categories All phone numbers fall into one of three categories Master Arming or Reporting as below Entering phone numbers into...

Страница 6: ...the panel The user code properties must be enabled for the specified command The action must be possible in the current panel status The command string must be correct and with all the required information The Add command is sent to add a new authorised phone number to the SMS Module You must specify whether the new phone number is a Master Phone Number User Phone Number or a Reporting Phone Numbe...

Отзывы: