6.
Repeat steps 4 and 5 to enter or change other user codes.
7.
Press [#] to exit the User Code Menu.
M A I N
M E N U
M
R
A
E
L
B
U
O
R
T
8.
Press [#] to exit the Main Menu.
0 1 / 0 1 / 9 9
0 : 0 4
R E A D Y
M O N
M
R
A
E
L
B
U
O
R
T
11.2 Deleting User Codes - LED Keypad
Follow steps 1-5 of the procedure in 11.1 but only press the [
] key in
step 6. That particular code will be deleted.
11.2.1 Deleting User Codes - LCD Keypad
Follow steps 1-8 of the procedure in 11.1.1 but only press the [
] key
in step 5. That particular code will be deleted.
12. Stay Zones
Stay zones are those zones which are bypassed automatically when
the system is
STAY ARMED
. To avoid triggering the alarm, zones
such as bedrooms, or other areas which require access, must be
bypassed. Stay zones need only be programmed once. Each time the
system is armed in the stay mode the pre selected stay zones will be
bypassed automatically.
12.1 To Program Stay Zones
[
3] + [ZONE NUMBER] + [
]+ [#]
1.
Hold down the [3] key until the keypad buzzer sounds.
2.
Press the [
NUMBER
] corresponding to the zone you wish to be a
STAY
zone followed by the [
] key.